基于最小负荷法的光伏系统电网渗透评估

Dawam Habibullah, Khin Moe Moe, Syafii Syafii
{"title":"基于最小负荷法的光伏系统电网渗透评估","authors":"Dawam Habibullah, Khin Moe Moe, Syafii Syafii","doi":"10.25077/aijaset.v3i2.95","DOIUrl":null,"url":null,"abstract":"The Indonesian government has also set a target to increase the contribution of renewable energy in the national energy mix to 23% by 2025 and 31% by 2050. In this paper, an analysis of Maximum PV Capacity was used on the transmission network with a minimum loading approach using the Power Factory15.1 simulation. From the simulation that has been done, it can be seen that the placement of two PV location points gets better results than the placement of one PV location point. This can be seen that the feeder load for PV location point of 74.3%, while for two PV location points of 35.8% which value is still within safe limits, but for two PV location points get better results. PV trip state frequency values obtained for single location point and two PV location points get a result of 2% of 50 Hz which is still within safe limits.","PeriodicalId":7884,"journal":{"name":"Andalasian International Journal of Applied Science, Engineering and Technology","volume":"81 21","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Photovoltaic Penetration on System Grid with Minimum Loading Approach\",\"authors\":\"Dawam Habibullah, Khin Moe Moe, Syafii Syafii\",\"doi\":\"10.25077/aijaset.v3i2.95\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Indonesian government has also set a target to increase the contribution of renewable energy in the national energy mix to 23% by 2025 and 31% by 2050. In this paper, an analysis of Maximum PV Capacity was used on the transmission network with a minimum loading approach using the Power Factory15.1 simulation. From the simulation that has been done, it can be seen that the placement of two PV location points gets better results than the placement of one PV location point. This can be seen that the feeder load for PV location point of 74.3%, while for two PV location points of 35.8% which value is still within safe limits, but for two PV location points get better results. PV trip state frequency values obtained for single location point and two PV location points get a result of 2% of 50 Hz which is still within safe limits.\",\"PeriodicalId\":7884,\"journal\":{\"name\":\"Andalasian International Journal of Applied Science, Engineering and Technology\",\"volume\":\"81 21\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Andalasian International Journal of Applied Science, Engineering and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25077/aijaset.v3i2.95\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Andalasian International Journal of Applied Science, Engineering and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25077/aijaset.v3i2.95","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

印尼政府还设定了一个目标,到2025年将可再生能源在国家能源结构中的贡献提高到23%,到2050年提高到31%。在本文中,使用Power Factory15.1仿真,分析了采用最小负荷方法的输电网络的最大光伏容量。从已经完成的仿真可以看出,放置两个PV定位点比放置一个PV定位点效果更好。由此可见,馈线负荷对于光伏定位点为74.3%,而对于两个光伏定位点为35.8%,其数值仍在安全范围内,但对于两个光伏定位点得到了较好的效果。单定位点和两个定位点的光伏脱扣状态频率值得到的结果为50 Hz的2%,仍在安全范围内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of Photovoltaic Penetration on System Grid with Minimum Loading Approach
The Indonesian government has also set a target to increase the contribution of renewable energy in the national energy mix to 23% by 2025 and 31% by 2050. In this paper, an analysis of Maximum PV Capacity was used on the transmission network with a minimum loading approach using the Power Factory15.1 simulation. From the simulation that has been done, it can be seen that the placement of two PV location points gets better results than the placement of one PV location point. This can be seen that the feeder load for PV location point of 74.3%, while for two PV location points of 35.8% which value is still within safe limits, but for two PV location points get better results. PV trip state frequency values obtained for single location point and two PV location points get a result of 2% of 50 Hz which is still within safe limits.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信