Indrani Pal, C. S. Stalin, Rwitika Chatterjee, Vivek K. Agrawal
{"title":"用IXPE观测IC 4329A的x射线偏振:对x射线日冕几何形状的约束","authors":"Indrani Pal, C. S. Stalin, Rwitika Chatterjee, Vivek K. Agrawal","doi":"10.1007/s12036-023-09981-5","DOIUrl":null,"url":null,"abstract":"<div><p>X-ray polarimetry is a powerful tool to probe the geometry of the hot X-ray corona in active galactic nuclei (AGN). Here, we present our results on the characterization of the X-ray polarization of the radio-quiet Seyfert-type AGN IC 4329A at a redshift of <span>\\(z = 0.016\\)</span>. This is based on observations carried out by the Imaging X-ray Polarimeter (IXPE). IXPE observed IC 4329A during 5–15 January 2023, for a total observing time of 458 ks. From the model-independent analysis, we found a polarization degree (<span>\\(\\Pi _{X}\\)</span>) of <span>\\(3.7\\pm 1.5\\)</span>% and a polarization position angle (<span>\\(\\Psi _{X}\\)</span>) of 61<span>\\(^{\\circ }\\pm 12^{\\circ }\\)</span> in the 2–8 keV energy range (at 68% confidence). This is also in agreement with the values of <span>\\(\\Pi _{X}\\)</span> and <span>\\(\\Psi _{X}\\)</span> of <span>\\(4.7\\pm 2.2\\)</span>% and <span>\\(71^{\\circ } \\pm 14^{\\circ }\\)</span>, respectively, obtained from spectro-polarimetric analysis of the I, Q and U Stokes spectra in the 2–8 keV energy band (at 90% confidence). The value of <span>\\(\\Pi _X\\)</span> in the 2–8 keV band obtained from the model-independent analysis is lower than the minimum detectable polarization (MDP) value of 4.5%. However, <span>\\(\\Pi _X\\)</span> obtained from spectro-polarimetric analysis in the 2–8 keV band is larger than the MDP value. In the 3–5 keV band, we found <span>\\(\\Pi _X\\)</span> of <span>\\(6.5 \\pm 1.8\\)</span>, which is larger than the MDP value of 5.5%. The observed moderate value of <span>\\(\\Pi _{X}\\)</span> obtained from the analysis of the IXPE data in the 3–5 keV band argues against a spherical lamp-post geometry for the X-ray corona in IC 4329A; however, considering simulations, the observed polarization measurements tend to favor a conical shape geometry for the corona. This is the first time measurement of X-ray polarization in IC 4329A. Measurements of the X-ray polarization in many such radio-quiet AGN will help in constraining the geometry of the X-ray corona in AGN.</p></div>","PeriodicalId":610,"journal":{"name":"Journal of Astrophysics and Astronomy","volume":"44 2","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2023-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"X-ray polarization observations of IC 4329A with IXPE: Constraining the geometry of X-ray corona\",\"authors\":\"Indrani Pal, C. S. Stalin, Rwitika Chatterjee, Vivek K. Agrawal\",\"doi\":\"10.1007/s12036-023-09981-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>X-ray polarimetry is a powerful tool to probe the geometry of the hot X-ray corona in active galactic nuclei (AGN). Here, we present our results on the characterization of the X-ray polarization of the radio-quiet Seyfert-type AGN IC 4329A at a redshift of <span>\\\\(z = 0.016\\\\)</span>. This is based on observations carried out by the Imaging X-ray Polarimeter (IXPE). IXPE observed IC 4329A during 5–15 January 2023, for a total observing time of 458 ks. From the model-independent analysis, we found a polarization degree (<span>\\\\(\\\\Pi _{X}\\\\)</span>) of <span>\\\\(3.7\\\\pm 1.5\\\\)</span>% and a polarization position angle (<span>\\\\(\\\\Psi _{X}\\\\)</span>) of 61<span>\\\\(^{\\\\circ }\\\\pm 12^{\\\\circ }\\\\)</span> in the 2–8 keV energy range (at 68% confidence). This is also in agreement with the values of <span>\\\\(\\\\Pi _{X}\\\\)</span> and <span>\\\\(\\\\Psi _{X}\\\\)</span> of <span>\\\\(4.7\\\\pm 2.2\\\\)</span>% and <span>\\\\(71^{\\\\circ } \\\\pm 14^{\\\\circ }\\\\)</span>, respectively, obtained from spectro-polarimetric analysis of the I, Q and U Stokes spectra in the 2–8 keV energy band (at 90% confidence). The value of <span>\\\\(\\\\Pi _X\\\\)</span> in the 2–8 keV band obtained from the model-independent analysis is lower than the minimum detectable polarization (MDP) value of 4.5%. However, <span>\\\\(\\\\Pi _X\\\\)</span> obtained from spectro-polarimetric analysis in the 2–8 keV band is larger than the MDP value. In the 3–5 keV band, we found <span>\\\\(\\\\Pi _X\\\\)</span> of <span>\\\\(6.5 \\\\pm 1.8\\\\)</span>, which is larger than the MDP value of 5.5%. The observed moderate value of <span>\\\\(\\\\Pi _{X}\\\\)</span> obtained from the analysis of the IXPE data in the 3–5 keV band argues against a spherical lamp-post geometry for the X-ray corona in IC 4329A; however, considering simulations, the observed polarization measurements tend to favor a conical shape geometry for the corona. This is the first time measurement of X-ray polarization in IC 4329A. Measurements of the X-ray polarization in many such radio-quiet AGN will help in constraining the geometry of the X-ray corona in AGN.</p></div>\",\"PeriodicalId\":610,\"journal\":{\"name\":\"Journal of Astrophysics and Astronomy\",\"volume\":\"44 2\",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-10-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Astrophysics and Astronomy\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s12036-023-09981-5\",\"RegionNum\":4,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ASTRONOMY & ASTROPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Astrophysics and Astronomy","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.1007/s12036-023-09981-5","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ASTRONOMY & ASTROPHYSICS","Score":null,"Total":0}
引用次数: 0
摘要
x射线偏振法是探测活动星系核(AGN)中热x射线日冕几何结构的有力工具。在这里,我们展示了我们在红移\(z = 0.016\)处的无线电静音seyfert型AGN IC 4329A的x射线偏振特性的结果。这是基于成像x射线偏振计(IXPE)进行的观测。IXPE在2023年1月5日至15日对IC 4329A进行了观测,总观测时间为458 ks。从与模型无关的分析中,我们发现极化度(\(\Pi _{X}\))为 \(3.7\pm 1.5\)% and a polarization position angle (\(\Psi _{X}\)) of 61\(^{\circ }\pm 12^{\circ }\) in the 2–8 keV energy range (at 68% confidence). This is also in agreement with the values of \(\Pi _{X}\) and \(\Psi _{X}\) of \(4.7\pm 2.2\)% and \(71^{\circ } \pm 14^{\circ }\), respectively, obtained from spectro-polarimetric analysis of the I, Q and U Stokes spectra in the 2–8 keV energy band (at 90% confidence). The value of \(\Pi _X\) in the 2–8 keV band obtained from the model-independent analysis is lower than the minimum detectable polarization (MDP) value of 4.5%. However, \(\Pi _X\) obtained from spectro-polarimetric analysis in the 2–8 keV band is larger than the MDP value. In the 3–5 keV band, we found \(\Pi _X\) of \(6.5 \pm 1.8\), which is larger than the MDP value of 5.5%. The observed moderate value of \(\Pi _{X}\) obtained from the analysis of the IXPE data in the 3–5 keV band argues against a spherical lamp-post geometry for the X-ray corona in IC 4329A; however, considering simulations, the observed polarization measurements tend to favor a conical shape geometry for the corona. This is the first time measurement of X-ray polarization in IC 4329A. Measurements of the X-ray polarization in many such radio-quiet AGN will help in constraining the geometry of the X-ray corona in AGN.
X-ray polarization observations of IC 4329A with IXPE: Constraining the geometry of X-ray corona
X-ray polarimetry is a powerful tool to probe the geometry of the hot X-ray corona in active galactic nuclei (AGN). Here, we present our results on the characterization of the X-ray polarization of the radio-quiet Seyfert-type AGN IC 4329A at a redshift of \(z = 0.016\). This is based on observations carried out by the Imaging X-ray Polarimeter (IXPE). IXPE observed IC 4329A during 5–15 January 2023, for a total observing time of 458 ks. From the model-independent analysis, we found a polarization degree (\(\Pi _{X}\)) of \(3.7\pm 1.5\)% and a polarization position angle (\(\Psi _{X}\)) of 61\(^{\circ }\pm 12^{\circ }\) in the 2–8 keV energy range (at 68% confidence). This is also in agreement with the values of \(\Pi _{X}\) and \(\Psi _{X}\) of \(4.7\pm 2.2\)% and \(71^{\circ } \pm 14^{\circ }\), respectively, obtained from spectro-polarimetric analysis of the I, Q and U Stokes spectra in the 2–8 keV energy band (at 90% confidence). The value of \(\Pi _X\) in the 2–8 keV band obtained from the model-independent analysis is lower than the minimum detectable polarization (MDP) value of 4.5%. However, \(\Pi _X\) obtained from spectro-polarimetric analysis in the 2–8 keV band is larger than the MDP value. In the 3–5 keV band, we found \(\Pi _X\) of \(6.5 \pm 1.8\), which is larger than the MDP value of 5.5%. The observed moderate value of \(\Pi _{X}\) obtained from the analysis of the IXPE data in the 3–5 keV band argues against a spherical lamp-post geometry for the X-ray corona in IC 4329A; however, considering simulations, the observed polarization measurements tend to favor a conical shape geometry for the corona. This is the first time measurement of X-ray polarization in IC 4329A. Measurements of the X-ray polarization in many such radio-quiet AGN will help in constraining the geometry of the X-ray corona in AGN.
期刊介绍:
The journal publishes original research papers on all aspects of astrophysics and astronomy, including instrumentation, laboratory astrophysics, and cosmology. Critical reviews of topical fields are also published.
Articles submitted as letters will be considered.