{"title":"采用Simplex架构进行安全在线控制系统升级","authors":"D. Seto, B. Krogh, L. Sha, A. Chutinan","doi":"10.1109/ACC.1998.703255","DOIUrl":null,"url":null,"abstract":"We describe the Simplex architecture, a real-time software technology which supports the safe, reliable introduction of control system upgrades while the system is running. We introduce its basic structure in control systems, discuss its fault-tolerance feature, and investigate the control issues when the technology is employed. Application of the Simplex architecture is demonstrated for a plasma-enhanced chemical vapor deposition (PECVD) system, a standard process in semiconductor manufacturing. We conclude the paper with a discussion of the potential impact that the Simplex architecture can make on future control applications.","PeriodicalId":364267,"journal":{"name":"Proceedings of the 1998 American Control Conference. ACC (IEEE Cat. No.98CH36207)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"115","resultStr":"{\"title\":\"The Simplex architecture for safe online control system upgrades\",\"authors\":\"D. Seto, B. Krogh, L. Sha, A. Chutinan\",\"doi\":\"10.1109/ACC.1998.703255\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We describe the Simplex architecture, a real-time software technology which supports the safe, reliable introduction of control system upgrades while the system is running. We introduce its basic structure in control systems, discuss its fault-tolerance feature, and investigate the control issues when the technology is employed. Application of the Simplex architecture is demonstrated for a plasma-enhanced chemical vapor deposition (PECVD) system, a standard process in semiconductor manufacturing. We conclude the paper with a discussion of the potential impact that the Simplex architecture can make on future control applications.\",\"PeriodicalId\":364267,\"journal\":{\"name\":\"Proceedings of the 1998 American Control Conference. ACC (IEEE Cat. No.98CH36207)\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-06-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"115\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 1998 American Control Conference. ACC (IEEE Cat. No.98CH36207)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ACC.1998.703255\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1998 American Control Conference. ACC (IEEE Cat. No.98CH36207)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ACC.1998.703255","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The Simplex architecture for safe online control system upgrades
We describe the Simplex architecture, a real-time software technology which supports the safe, reliable introduction of control system upgrades while the system is running. We introduce its basic structure in control systems, discuss its fault-tolerance feature, and investigate the control issues when the technology is employed. Application of the Simplex architecture is demonstrated for a plasma-enhanced chemical vapor deposition (PECVD) system, a standard process in semiconductor manufacturing. We conclude the paper with a discussion of the potential impact that the Simplex architecture can make on future control applications.