C. Stein, H.A. Grundlong, H. Pinheiro, J. R. Pinheiro, H. Hey
{"title":"软过渡逆变器的分析与比较","authors":"C. Stein, H.A. Grundlong, H. Pinheiro, J. R. Pinheiro, H. Hey","doi":"10.1109/ISIE.2003.1267308","DOIUrl":null,"url":null,"abstract":"This paper presents a comparative analysis of a set of soft-transition techniques applied in inverters utilizing IGBT as power switches. The techniques are compared based in losses, number of components, stresses and type of commutation obtained. An estimation of power losses and junction temperature of insulated gate bipolar transistor (IGBT) devices is used to compare the soft-transition techniques. The method used to estimate the losses and temperatures is based in the data obtained from the devices data sheets and in the governing equation of the auxiliary circuits. This method uses a program written in MATLAB, which make use of an iterative process to obtain the convergence of the values of losses and temperature. Experimental results of the soft-transition techniques are presented, as well as a discussion about their characteristics.","PeriodicalId":166431,"journal":{"name":"2003 IEEE International Symposium on Industrial Electronics ( Cat. No.03TH8692)","volume":"16 3","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Analysis and comparison of soft-transition inverters\",\"authors\":\"C. Stein, H.A. Grundlong, H. Pinheiro, J. R. Pinheiro, H. Hey\",\"doi\":\"10.1109/ISIE.2003.1267308\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a comparative analysis of a set of soft-transition techniques applied in inverters utilizing IGBT as power switches. The techniques are compared based in losses, number of components, stresses and type of commutation obtained. An estimation of power losses and junction temperature of insulated gate bipolar transistor (IGBT) devices is used to compare the soft-transition techniques. The method used to estimate the losses and temperatures is based in the data obtained from the devices data sheets and in the governing equation of the auxiliary circuits. This method uses a program written in MATLAB, which make use of an iterative process to obtain the convergence of the values of losses and temperature. Experimental results of the soft-transition techniques are presented, as well as a discussion about their characteristics.\",\"PeriodicalId\":166431,\"journal\":{\"name\":\"2003 IEEE International Symposium on Industrial Electronics ( Cat. No.03TH8692)\",\"volume\":\"16 3\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-06-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 IEEE International Symposium on Industrial Electronics ( Cat. No.03TH8692)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISIE.2003.1267308\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE International Symposium on Industrial Electronics ( Cat. No.03TH8692)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.2003.1267308","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文对采用IGBT作为功率开关的逆变器中的一组软过渡技术进行了比较分析。基于损耗、元件数量、应力和获得的换相类型对这些技术进行了比较。通过对绝缘栅双极晶体管(IGBT)器件的功率损耗和结温的估计,对软转换技术进行了比较。用于估计损耗和温度的方法是基于从器件数据表和辅助电路的控制方程中获得的数据。该方法采用MATLAB编写的程序,利用迭代过程求得损耗值和温度值的收敛性。给出了软过渡技术的实验结果,并对其特点进行了讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis and comparison of soft-transition inverters
This paper presents a comparative analysis of a set of soft-transition techniques applied in inverters utilizing IGBT as power switches. The techniques are compared based in losses, number of components, stresses and type of commutation obtained. An estimation of power losses and junction temperature of insulated gate bipolar transistor (IGBT) devices is used to compare the soft-transition techniques. The method used to estimate the losses and temperatures is based in the data obtained from the devices data sheets and in the governing equation of the auxiliary circuits. This method uses a program written in MATLAB, which make use of an iterative process to obtain the convergence of the values of losses and temperature. Experimental results of the soft-transition techniques are presented, as well as a discussion about their characteristics.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信