单相并网太阳能光伏逆变器对市电电压和频率波动的响应

K. J. Kumar, R. S. Kumar
{"title":"单相并网太阳能光伏逆变器对市电电压和频率波动的响应","authors":"K. J. Kumar, R. S. Kumar","doi":"10.1109/GlobConHT56829.2023.10087718","DOIUrl":null,"url":null,"abstract":"This paper aims to check the voltage and frequency response of a single-phase solar PV grid inverter with an output of 4 kW in the event of over / under voltage and over/under frequency fluctuations. The inverter voltage and frequency performance are verified against compliance with IS/IEC 61727: 2004 (Indian standard) and the proposed method. The study shows that in the event of an abnormal grid frequency with a deviation of ± 1.5 Hz, the grid-connected inverter trips within limits and meets the requirements of the standard and the proposed method. In contrast to the abnormal frequency condition, the inverter has exceeded the 0.1-second limit during an abnormal voltage condition (under-voltage at 105 V). The proposed method is validated, and the results are provided.","PeriodicalId":355921,"journal":{"name":"2023 IEEE IAS Global Conference on Renewable Energy and Hydrogen Technologies (GlobConHT)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Response of Single-Phase Grid-Tied Solar PV Inverter During Utility Voltage and Frequency Fluctuations\",\"authors\":\"K. J. Kumar, R. S. Kumar\",\"doi\":\"10.1109/GlobConHT56829.2023.10087718\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper aims to check the voltage and frequency response of a single-phase solar PV grid inverter with an output of 4 kW in the event of over / under voltage and over/under frequency fluctuations. The inverter voltage and frequency performance are verified against compliance with IS/IEC 61727: 2004 (Indian standard) and the proposed method. The study shows that in the event of an abnormal grid frequency with a deviation of ± 1.5 Hz, the grid-connected inverter trips within limits and meets the requirements of the standard and the proposed method. In contrast to the abnormal frequency condition, the inverter has exceeded the 0.1-second limit during an abnormal voltage condition (under-voltage at 105 V). The proposed method is validated, and the results are provided.\",\"PeriodicalId\":355921,\"journal\":{\"name\":\"2023 IEEE IAS Global Conference on Renewable Energy and Hydrogen Technologies (GlobConHT)\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 IEEE IAS Global Conference on Renewable Energy and Hydrogen Technologies (GlobConHT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/GlobConHT56829.2023.10087718\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 IEEE IAS Global Conference on Renewable Energy and Hydrogen Technologies (GlobConHT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/GlobConHT56829.2023.10087718","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文旨在研究输出功率为4kw的单相太阳能光伏并网逆变器在电压过欠和频率过欠波动情况下的电压响应和频率响应。根据IS/IEC 61727: 2004(印度标准)和提出的方法验证了逆变器的电压和频率性能。研究表明,在电网频率偏差为±1.5 Hz的异常情况下,并网逆变器在限制范围内跳闸,满足标准和提出的方法的要求。与频率异常情况相比,在电压异常情况下(105v欠压)逆变器超过了0.1秒的限制。验证了所提方法,并给出了结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Response of Single-Phase Grid-Tied Solar PV Inverter During Utility Voltage and Frequency Fluctuations
This paper aims to check the voltage and frequency response of a single-phase solar PV grid inverter with an output of 4 kW in the event of over / under voltage and over/under frequency fluctuations. The inverter voltage and frequency performance are verified against compliance with IS/IEC 61727: 2004 (Indian standard) and the proposed method. The study shows that in the event of an abnormal grid frequency with a deviation of ± 1.5 Hz, the grid-connected inverter trips within limits and meets the requirements of the standard and the proposed method. In contrast to the abnormal frequency condition, the inverter has exceeded the 0.1-second limit during an abnormal voltage condition (under-voltage at 105 V). The proposed method is validated, and the results are provided.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信