[远程治疗的通用验证和协议系统]。

Radiobiologia, radiotherapia Pub Date : 1990-01-01
H P Brasching, H Franz, P Geyer, D Lehmann, J Lorenz, H Röthig, B Theilig, L Voigtmann
{"title":"[远程治疗的通用验证和协议系统]。","authors":"H P Brasching,&nbsp;H Franz,&nbsp;P Geyer,&nbsp;D Lehmann,&nbsp;J Lorenz,&nbsp;H Röthig,&nbsp;B Theilig,&nbsp;L Voigtmann","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>To increase the quality of radiotherapy a verify and record system (VPS) was developed for teletherapy equipments, that takes control of manually adjusted irradiation parameters and of recording all relevant data of radiotherapy. The VPS can be adapted to special wishes of the user and it lends itself to application on different irradiation equipments. In the represented paper especially the extent of efficiency of the system is shown which is characterized by high operating comfort, flexible reacting to exceptional cases and by high date and operating security. The testing phase on an accelerator model has been brought to a close, actually the system is installed to an electron linear accelerator \"Neptun 10p\" and led to clinical trial.</p>","PeriodicalId":76404,"journal":{"name":"Radiobiologia, radiotherapia","volume":"31 5","pages":"437-48"},"PeriodicalIF":0.0000,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[A universal verification and protocol system for teletherapy].\",\"authors\":\"H P Brasching,&nbsp;H Franz,&nbsp;P Geyer,&nbsp;D Lehmann,&nbsp;J Lorenz,&nbsp;H Röthig,&nbsp;B Theilig,&nbsp;L Voigtmann\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>To increase the quality of radiotherapy a verify and record system (VPS) was developed for teletherapy equipments, that takes control of manually adjusted irradiation parameters and of recording all relevant data of radiotherapy. The VPS can be adapted to special wishes of the user and it lends itself to application on different irradiation equipments. In the represented paper especially the extent of efficiency of the system is shown which is characterized by high operating comfort, flexible reacting to exceptional cases and by high date and operating security. The testing phase on an accelerator model has been brought to a close, actually the system is installed to an electron linear accelerator \\\"Neptun 10p\\\" and led to clinical trial.</p>\",\"PeriodicalId\":76404,\"journal\":{\"name\":\"Radiobiologia, radiotherapia\",\"volume\":\"31 5\",\"pages\":\"437-48\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiobiologia, radiotherapia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiobiologia, radiotherapia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了提高放射治疗的质量,研制了一种远程治疗设备的验证和记录系统(VPS),该系统可以控制人工调节的放射参数并记录放射治疗的所有相关数据。VPS可根据用户的特殊要求进行调整,适用于不同的辐照设备。在本文中,特别指出了该系统的效率程度,其特点是高操作舒适性,对异常情况的灵活反应以及高数据和操作安全性。在加速器模型上的测试阶段已经结束,实际将系统安装到电子直线加速器“海王星10p”上并进行临床试验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[A universal verification and protocol system for teletherapy].

To increase the quality of radiotherapy a verify and record system (VPS) was developed for teletherapy equipments, that takes control of manually adjusted irradiation parameters and of recording all relevant data of radiotherapy. The VPS can be adapted to special wishes of the user and it lends itself to application on different irradiation equipments. In the represented paper especially the extent of efficiency of the system is shown which is characterized by high operating comfort, flexible reacting to exceptional cases and by high date and operating security. The testing phase on an accelerator model has been brought to a close, actually the system is installed to an electron linear accelerator "Neptun 10p" and led to clinical trial.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信