{"title":"OSL与腔室辐射抗扰度测量比较","authors":"Tae-Heon Jang, Won-seo Cho","doi":"10.1109/EMCZUR.2006.214975","DOIUrl":null,"url":null,"abstract":"In CISPR 20, radiated immunity test is performed in the open stripline (OSL) which height is 0.8 m. CISPR 20 also specifies that equipment not fitting inside open stripline shall be measured according to IEC 61000-4-3 in frequency range of 80 MHz to 150 MHz with the same limits as in the OSL. In this paper, the analysis of the field distribution in the OSL was completed by moment method and the testing according to both methods was carried out and the immunity level has compared. The result shows that the testing in chamber is more severe than in OSL","PeriodicalId":130489,"journal":{"name":"2006 17th International Zurich Symposium on Electromagnetic Compatibility","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Radiated immunity measurement comparison between OSL and chamber\",\"authors\":\"Tae-Heon Jang, Won-seo Cho\",\"doi\":\"10.1109/EMCZUR.2006.214975\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In CISPR 20, radiated immunity test is performed in the open stripline (OSL) which height is 0.8 m. CISPR 20 also specifies that equipment not fitting inside open stripline shall be measured according to IEC 61000-4-3 in frequency range of 80 MHz to 150 MHz with the same limits as in the OSL. In this paper, the analysis of the field distribution in the OSL was completed by moment method and the testing according to both methods was carried out and the immunity level has compared. The result shows that the testing in chamber is more severe than in OSL\",\"PeriodicalId\":130489,\"journal\":{\"name\":\"2006 17th International Zurich Symposium on Electromagnetic Compatibility\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-05-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 17th International Zurich Symposium on Electromagnetic Compatibility\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EMCZUR.2006.214975\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 17th International Zurich Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCZUR.2006.214975","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Radiated immunity measurement comparison between OSL and chamber
In CISPR 20, radiated immunity test is performed in the open stripline (OSL) which height is 0.8 m. CISPR 20 also specifies that equipment not fitting inside open stripline shall be measured according to IEC 61000-4-3 in frequency range of 80 MHz to 150 MHz with the same limits as in the OSL. In this paper, the analysis of the field distribution in the OSL was completed by moment method and the testing according to both methods was carried out and the immunity level has compared. The result shows that the testing in chamber is more severe than in OSL