运行振动试验-电信电力设备的NEBS地震试验的替代方案

B. Serban
{"title":"运行振动试验-电信电力设备的NEBS地震试验的替代方案","authors":"B. Serban","doi":"10.1109/INTLEC.2006.251643","DOIUrl":null,"url":null,"abstract":"Power systems for telecommunications are required to function at high level of reliability in harsh environmental conditions of vibrations, shocks and earthquakes. The main objective of this paper is to discuss the Operational Vibration Test as an alternative to the NEBS seismic test of power equipment at shelf level. The paper discusses the rationale for an alternative to NEBS seismic test, the theoretical background, and presents a case study of power equipment shelf and distribution. Finally, the paper shows that the alternative test is more cost effective than a full seismic test and could be used for power equipment design in a timely manner","PeriodicalId":356699,"journal":{"name":"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Operational Vibration Test- An Alternative to NEBS Seismic Test for Telecom Power Equipment\",\"authors\":\"B. Serban\",\"doi\":\"10.1109/INTLEC.2006.251643\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power systems for telecommunications are required to function at high level of reliability in harsh environmental conditions of vibrations, shocks and earthquakes. The main objective of this paper is to discuss the Operational Vibration Test as an alternative to the NEBS seismic test of power equipment at shelf level. The paper discusses the rationale for an alternative to NEBS seismic test, the theoretical background, and presents a case study of power equipment shelf and distribution. Finally, the paper shows that the alternative test is more cost effective than a full seismic test and could be used for power equipment design in a timely manner\",\"PeriodicalId\":356699,\"journal\":{\"name\":\"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INTLEC.2006.251643\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTLEC.2006.251643","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

电信电力系统需要在振动、冲击和地震等恶劣环境条件下以高可靠性运行。本文的主要目的是讨论运行振动试验作为NEBS地震试验在货架水平电力设备的替代方案。本文讨论了替代NEBS地震试验的基本原理、理论背景,并以电力设备架架和配电为例进行了分析。最后,本文表明替代试验比完整的地震试验更具成本效益,可以及时用于电力设备的设计
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Operational Vibration Test- An Alternative to NEBS Seismic Test for Telecom Power Equipment
Power systems for telecommunications are required to function at high level of reliability in harsh environmental conditions of vibrations, shocks and earthquakes. The main objective of this paper is to discuss the Operational Vibration Test as an alternative to the NEBS seismic test of power equipment at shelf level. The paper discusses the rationale for an alternative to NEBS seismic test, the theoretical background, and presents a case study of power equipment shelf and distribution. Finally, the paper shows that the alternative test is more cost effective than a full seismic test and could be used for power equipment design in a timely manner
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信