F J Van de Velde, G T Timberlake, A E Jalkh, C L Schepens
{"title":"【激光扫描检眼镜静态显微术】。","authors":"F J Van de Velde, G T Timberlake, A E Jalkh, C L Schepens","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>We have used the scanning laser opthalmoscope (SLO) with a personal computer to develop static microperimetry techniques. They allow to see in real-time on a television monitor the precise retinal localization of the stimulus and fixation. The testing is performed under strict conditions. The size of stimuli can vary between 6 and 30 minarc on a side. 255 different intensity levels are possible with the instrument. We have selected 12 of them, representing a logarithmic scale. Stimulus duration can vary between 50 and 500 ms. Examples of macular pathology including subretinal neovascularization, drusen and macular edema are given.</p>","PeriodicalId":77584,"journal":{"name":"Ophtalmologie : organe de la Societe francaise d'ophtalmologie","volume":"4 3","pages":"291-4"},"PeriodicalIF":0.0000,"publicationDate":"1990-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Static microperimetry with the laser scanning ophthalmoscope].\",\"authors\":\"F J Van de Velde, G T Timberlake, A E Jalkh, C L Schepens\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We have used the scanning laser opthalmoscope (SLO) with a personal computer to develop static microperimetry techniques. They allow to see in real-time on a television monitor the precise retinal localization of the stimulus and fixation. The testing is performed under strict conditions. The size of stimuli can vary between 6 and 30 minarc on a side. 255 different intensity levels are possible with the instrument. We have selected 12 of them, representing a logarithmic scale. Stimulus duration can vary between 50 and 500 ms. Examples of macular pathology including subretinal neovascularization, drusen and macular edema are given.</p>\",\"PeriodicalId\":77584,\"journal\":{\"name\":\"Ophtalmologie : organe de la Societe francaise d'ophtalmologie\",\"volume\":\"4 3\",\"pages\":\"291-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophtalmologie : organe de la Societe francaise d'ophtalmologie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophtalmologie : organe de la Societe francaise d'ophtalmologie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Static microperimetry with the laser scanning ophthalmoscope].
We have used the scanning laser opthalmoscope (SLO) with a personal computer to develop static microperimetry techniques. They allow to see in real-time on a television monitor the precise retinal localization of the stimulus and fixation. The testing is performed under strict conditions. The size of stimuli can vary between 6 and 30 minarc on a side. 255 different intensity levels are possible with the instrument. We have selected 12 of them, representing a logarithmic scale. Stimulus duration can vary between 50 and 500 ms. Examples of macular pathology including subretinal neovascularization, drusen and macular edema are given.