一种基于ZIF-8涂层电耦合石英晶体微天平的气体传感器

B. Madeira, Benzheng Xia, Yuan Wang, R. Ameloot, M. Kraft, Chen Wang
{"title":"一种基于ZIF-8涂层电耦合石英晶体微天平的气体传感器","authors":"B. Madeira, Benzheng Xia, Yuan Wang, R. Ameloot, M. Kraft, Chen Wang","doi":"10.1109/SENSORS52175.2022.9967087","DOIUrl":null,"url":null,"abstract":"This paper reported a gas sensor based on two quartz crystal microbalances (QCM) weakly coupled through a capacitor (electrically). By coating one of the two QCMs with zeolitic imidazolate framework-8 (ZIF-8), the coated QCM could adsorb/desorb gas molecules, e.g., ethanol molecules, thus breaking the mass symmetry of the coupled system. The mass change due to gas absorption and desorption was measured through the amplitude ratio and the frequency shift of coupled QCMs. The gas sensor operated in an open-loop and closed-loop configuration whose performances were compared. Three orders of magnitude improvement was achieved by using the amplitude ratio change as the output compared to using the frequency shift as the output in the closed-loop configuration. Besides, the closed-loop configuration improved the amplitude ratio sensitivity by 50.2% compared with the open-loop configuration.","PeriodicalId":120357,"journal":{"name":"2022 IEEE Sensors","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A Gas Sensor Based on Electrically Coupled Quartz Crystal Microbalances Coated with ZIF-8\",\"authors\":\"B. Madeira, Benzheng Xia, Yuan Wang, R. Ameloot, M. Kraft, Chen Wang\",\"doi\":\"10.1109/SENSORS52175.2022.9967087\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper reported a gas sensor based on two quartz crystal microbalances (QCM) weakly coupled through a capacitor (electrically). By coating one of the two QCMs with zeolitic imidazolate framework-8 (ZIF-8), the coated QCM could adsorb/desorb gas molecules, e.g., ethanol molecules, thus breaking the mass symmetry of the coupled system. The mass change due to gas absorption and desorption was measured through the amplitude ratio and the frequency shift of coupled QCMs. The gas sensor operated in an open-loop and closed-loop configuration whose performances were compared. Three orders of magnitude improvement was achieved by using the amplitude ratio change as the output compared to using the frequency shift as the output in the closed-loop configuration. Besides, the closed-loop configuration improved the amplitude ratio sensitivity by 50.2% compared with the open-loop configuration.\",\"PeriodicalId\":120357,\"journal\":{\"name\":\"2022 IEEE Sensors\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE Sensors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SENSORS52175.2022.9967087\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Sensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SENSORS52175.2022.9967087","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文报道了一种基于两个石英晶体微天平(QCM)通过电容弱耦合的气体传感器。通过将沸石咪唑酸框架-8 (ZIF-8)包覆在其中一种QCM上,被包覆的QCM可以吸附/解吸气体分子,如乙醇分子,从而破坏耦合体系的质量对称性。通过耦合qcm的幅值比和频移测量了气体吸收和解吸引起的质量变化。比较了该气体传感器在开环和闭环两种结构下的工作性能。在闭环配置中,与使用频移作为输出相比,使用幅度比变化作为输出实现了三个数量级的改进。与开环结构相比,闭环结构的幅比灵敏度提高了50.2%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Gas Sensor Based on Electrically Coupled Quartz Crystal Microbalances Coated with ZIF-8
This paper reported a gas sensor based on two quartz crystal microbalances (QCM) weakly coupled through a capacitor (electrically). By coating one of the two QCMs with zeolitic imidazolate framework-8 (ZIF-8), the coated QCM could adsorb/desorb gas molecules, e.g., ethanol molecules, thus breaking the mass symmetry of the coupled system. The mass change due to gas absorption and desorption was measured through the amplitude ratio and the frequency shift of coupled QCMs. The gas sensor operated in an open-loop and closed-loop configuration whose performances were compared. Three orders of magnitude improvement was achieved by using the amplitude ratio change as the output compared to using the frequency shift as the output in the closed-loop configuration. Besides, the closed-loop configuration improved the amplitude ratio sensitivity by 50.2% compared with the open-loop configuration.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信