T Andersen, P J Jørgensen, E Toft, L K Nielsen, K N Hansen
{"title":"用乳胶凝集试验(Rapi-Tex)快速估计横纹肌溶解期间血清肌红蛋白浓度。","authors":"T Andersen, P J Jørgensen, E Toft, L K Nielsen, K N Hansen","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A latex-agglutination test (Rapi-Tex) was used for semiquantitative estimation of myoglobin concentration in 89 serum samples obtained from ten patients undergoing lower-limb arterial embolectomy. Each serum sample was tested with Rapi-Tex both undiluted and after 1:50 dilution with saline. The myoglobin concentration was additionally measured with enzyme-immunoassay. In the undiluted samples there were five 'false negative' Rapi-Tex results--two in the myoglobin concentration interval 0-300 micrograms and three in the samples with myoglobin exceeding 25,000 micrograms/l--and four 'false positive' results. None of the diluted samples gave rise to false classification. Using 1:50 diluted serum, the negative predictive value of the Rapi-Tex test for identification of a myoglobin concentration greater than 5,000 micrograms/l was 0.99 (95% confidence limits 0.94-1.00), and the positive predictive value was 1.00 (0.61-1.00). Rapi-tex is concluded to be a useful emergency test for severe hypermyoglobinemia.</p>","PeriodicalId":7005,"journal":{"name":"Acta chirurgica Scandinavica","volume":"156 8","pages":"515-9"},"PeriodicalIF":0.0000,"publicationDate":"1990-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rapid estimation of serum myoglobin concentration during rhabdomyolysis with a latex-agglutination test (Rapi-Tex).\",\"authors\":\"T Andersen, P J Jørgensen, E Toft, L K Nielsen, K N Hansen\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A latex-agglutination test (Rapi-Tex) was used for semiquantitative estimation of myoglobin concentration in 89 serum samples obtained from ten patients undergoing lower-limb arterial embolectomy. Each serum sample was tested with Rapi-Tex both undiluted and after 1:50 dilution with saline. The myoglobin concentration was additionally measured with enzyme-immunoassay. In the undiluted samples there were five 'false negative' Rapi-Tex results--two in the myoglobin concentration interval 0-300 micrograms and three in the samples with myoglobin exceeding 25,000 micrograms/l--and four 'false positive' results. None of the diluted samples gave rise to false classification. Using 1:50 diluted serum, the negative predictive value of the Rapi-Tex test for identification of a myoglobin concentration greater than 5,000 micrograms/l was 0.99 (95% confidence limits 0.94-1.00), and the positive predictive value was 1.00 (0.61-1.00). Rapi-tex is concluded to be a useful emergency test for severe hypermyoglobinemia.</p>\",\"PeriodicalId\":7005,\"journal\":{\"name\":\"Acta chirurgica Scandinavica\",\"volume\":\"156 8\",\"pages\":\"515-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta chirurgica Scandinavica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta chirurgica Scandinavica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Rapid estimation of serum myoglobin concentration during rhabdomyolysis with a latex-agglutination test (Rapi-Tex).
A latex-agglutination test (Rapi-Tex) was used for semiquantitative estimation of myoglobin concentration in 89 serum samples obtained from ten patients undergoing lower-limb arterial embolectomy. Each serum sample was tested with Rapi-Tex both undiluted and after 1:50 dilution with saline. The myoglobin concentration was additionally measured with enzyme-immunoassay. In the undiluted samples there were five 'false negative' Rapi-Tex results--two in the myoglobin concentration interval 0-300 micrograms and three in the samples with myoglobin exceeding 25,000 micrograms/l--and four 'false positive' results. None of the diluted samples gave rise to false classification. Using 1:50 diluted serum, the negative predictive value of the Rapi-Tex test for identification of a myoglobin concentration greater than 5,000 micrograms/l was 0.99 (95% confidence limits 0.94-1.00), and the positive predictive value was 1.00 (0.61-1.00). Rapi-tex is concluded to be a useful emergency test for severe hypermyoglobinemia.