一种单相电压源逆变器无传感器电网电压估计方案

A. Mirza, I. Nutkani, C. Teixeira, B. Mcgrath
{"title":"一种单相电压源逆变器无传感器电网电压估计方案","authors":"A. Mirza, I. Nutkani, C. Teixeira, B. Mcgrath","doi":"10.23919/ICPE2023-ECCEAsia54778.2023.10213876","DOIUrl":null,"url":null,"abstract":"Synchronisation is an essential operational requirement for grid-connected voltage source inverters (VSIs). Several schemes have been proposed to maintain synchronisation without using voltage sensors. However, establishing the initial synchronisation without voltage sensors remains challenging because of the absence of the grid voltage magnitude and phase information. This paper presents a grid voltage estimation scheme for single-phase VSIs that uses a startup pulse width modulation (PWM) control approach, which constrains the modulation depth such that the inverter current is mainly driven by the grid voltage. This allows the accurate detection of the grid voltage magnitude and phase from the switched inverter current measurement. A mathematical model with key analytical design equations is presented. The scheme’s voltage estimation accuracy and its application for grid synchronisation are validated using switched simulations in Altair PSIM.","PeriodicalId":151155,"journal":{"name":"2023 11th International Conference on Power Electronics and ECCE Asia (ICPE 2023 - ECCE Asia)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Sensorless Grid Voltage Estimation Scheme for a Single-phase Voltage Source Inverter\",\"authors\":\"A. Mirza, I. Nutkani, C. Teixeira, B. Mcgrath\",\"doi\":\"10.23919/ICPE2023-ECCEAsia54778.2023.10213876\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Synchronisation is an essential operational requirement for grid-connected voltage source inverters (VSIs). Several schemes have been proposed to maintain synchronisation without using voltage sensors. However, establishing the initial synchronisation without voltage sensors remains challenging because of the absence of the grid voltage magnitude and phase information. This paper presents a grid voltage estimation scheme for single-phase VSIs that uses a startup pulse width modulation (PWM) control approach, which constrains the modulation depth such that the inverter current is mainly driven by the grid voltage. This allows the accurate detection of the grid voltage magnitude and phase from the switched inverter current measurement. A mathematical model with key analytical design equations is presented. The scheme’s voltage estimation accuracy and its application for grid synchronisation are validated using switched simulations in Altair PSIM.\",\"PeriodicalId\":151155,\"journal\":{\"name\":\"2023 11th International Conference on Power Electronics and ECCE Asia (ICPE 2023 - ECCE Asia)\",\"volume\":\"30 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 11th International Conference on Power Electronics and ECCE Asia (ICPE 2023 - ECCE Asia)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/ICPE2023-ECCEAsia54778.2023.10213876\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 11th International Conference on Power Electronics and ECCE Asia (ICPE 2023 - ECCE Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/ICPE2023-ECCEAsia54778.2023.10213876","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

同步是并网电压源逆变器(vsi)的基本运行要求。已经提出了几种不使用电压传感器来保持同步的方案。然而,由于缺乏电网电压幅度和相位信息,在没有电压传感器的情况下建立初始同步仍然具有挑战性。本文提出了一种单相vsi的电网电压估计方案,该方案采用启动脉宽调制(PWM)控制方法,限制了调制深度,使逆变器电流主要由电网电压驱动。这允许从开关逆变器电流测量中准确检测电网电压幅度和相位。提出了一个具有关键分析设计方程的数学模型。通过Altair PSIM的切换仿真,验证了该方案的电压估计精度及其在电网同步中的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Sensorless Grid Voltage Estimation Scheme for a Single-phase Voltage Source Inverter
Synchronisation is an essential operational requirement for grid-connected voltage source inverters (VSIs). Several schemes have been proposed to maintain synchronisation without using voltage sensors. However, establishing the initial synchronisation without voltage sensors remains challenging because of the absence of the grid voltage magnitude and phase information. This paper presents a grid voltage estimation scheme for single-phase VSIs that uses a startup pulse width modulation (PWM) control approach, which constrains the modulation depth such that the inverter current is mainly driven by the grid voltage. This allows the accurate detection of the grid voltage magnitude and phase from the switched inverter current measurement. A mathematical model with key analytical design equations is presented. The scheme’s voltage estimation accuracy and its application for grid synchronisation are validated using switched simulations in Altair PSIM.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信