J. S. Farkhani, M. Zareein, H. Soroushmehr, H. Mortazavi
{"title":"暂态稳定下分布式发电的保护协调约束","authors":"J. S. Farkhani, M. Zareein, H. Soroushmehr, H. Mortazavi","doi":"10.1109/KBEI.2019.8734981","DOIUrl":null,"url":null,"abstract":"Transient stability analysis plays an important role in providing performance constraints in power systems. The penetration of distributed generation leads to performance constraints on the overcurrent relay setting.This paper investigates the transient stability analysis of real distribution network with DGs penetration for the protection overcurrent relay setting.For this purpose, the transient stability of DG generators is studied by taking into account faults in different places of the power system. Then, the constraints of DG generators are considered in relay coordination protection.The case study is based on a real distribution network that consists of two generators with 4 MW capacity, and the simulation is performed in DIgSILENT software.","PeriodicalId":339990,"journal":{"name":"2019 5th Conference on Knowledge Based Engineering and Innovation (KBEI)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Protection Coordination constraints of Distributed Generation in Transient Stability\",\"authors\":\"J. S. Farkhani, M. Zareein, H. Soroushmehr, H. Mortazavi\",\"doi\":\"10.1109/KBEI.2019.8734981\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Transient stability analysis plays an important role in providing performance constraints in power systems. The penetration of distributed generation leads to performance constraints on the overcurrent relay setting.This paper investigates the transient stability analysis of real distribution network with DGs penetration for the protection overcurrent relay setting.For this purpose, the transient stability of DG generators is studied by taking into account faults in different places of the power system. Then, the constraints of DG generators are considered in relay coordination protection.The case study is based on a real distribution network that consists of two generators with 4 MW capacity, and the simulation is performed in DIgSILENT software.\",\"PeriodicalId\":339990,\"journal\":{\"name\":\"2019 5th Conference on Knowledge Based Engineering and Innovation (KBEI)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 5th Conference on Knowledge Based Engineering and Innovation (KBEI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/KBEI.2019.8734981\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 5th Conference on Knowledge Based Engineering and Innovation (KBEI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/KBEI.2019.8734981","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Protection Coordination constraints of Distributed Generation in Transient Stability
Transient stability analysis plays an important role in providing performance constraints in power systems. The penetration of distributed generation leads to performance constraints on the overcurrent relay setting.This paper investigates the transient stability analysis of real distribution network with DGs penetration for the protection overcurrent relay setting.For this purpose, the transient stability of DG generators is studied by taking into account faults in different places of the power system. Then, the constraints of DG generators are considered in relay coordination protection.The case study is based on a real distribution network that consists of two generators with 4 MW capacity, and the simulation is performed in DIgSILENT software.