隔离式感应发电机的直接和间接磁通控制

R. Lyra, S. Silva, P. C. Cortizo
{"title":"隔离式感应发电机的直接和间接磁通控制","authors":"R. Lyra, S. Silva, P. C. Cortizo","doi":"10.1109/PEDS.1995.404933","DOIUrl":null,"url":null,"abstract":"This work presents an excitation control scheme for an induction generator using a PWM VAr compensator. The operation under variable speed conditions typical in wind drivers, the high performance, supported by the field oriented vector control and the total isolated operation, using a starting-up battery are the main features of this system. The vector control is implemented both in a direct field orientation scheme, using a stator flux observer, and in an indirect scheme, based on the voltage vector. In both methods, a DC voltage controller is used to maintain the necessary DC level in the compensator. The analysis is made by the aid of computer simulation and experimental results obtained from a 2 HP prototype.<<ETX>>","PeriodicalId":244042,"journal":{"name":"Proceedings of 1995 International Conference on Power Electronics and Drive Systems. PEDS 95","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-02-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"23","resultStr":"{\"title\":\"Direct and indirect flux control of an isolated induction generator\",\"authors\":\"R. Lyra, S. Silva, P. C. Cortizo\",\"doi\":\"10.1109/PEDS.1995.404933\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work presents an excitation control scheme for an induction generator using a PWM VAr compensator. The operation under variable speed conditions typical in wind drivers, the high performance, supported by the field oriented vector control and the total isolated operation, using a starting-up battery are the main features of this system. The vector control is implemented both in a direct field orientation scheme, using a stator flux observer, and in an indirect scheme, based on the voltage vector. In both methods, a DC voltage controller is used to maintain the necessary DC level in the compensator. The analysis is made by the aid of computer simulation and experimental results obtained from a 2 HP prototype.<<ETX>>\",\"PeriodicalId\":244042,\"journal\":{\"name\":\"Proceedings of 1995 International Conference on Power Electronics and Drive Systems. PEDS 95\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-02-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"23\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 1995 International Conference on Power Electronics and Drive Systems. PEDS 95\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEDS.1995.404933\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1995 International Conference on Power Electronics and Drive Systems. PEDS 95","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDS.1995.404933","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 23

摘要

本文提出了一种采用PWM无功补偿器的感应发电机励磁控制方案。该系统的主要特点是在风力驱动器中典型的变速条件下运行,由磁场定向矢量控制支持的高性能和使用启动电池的完全隔离运行。矢量控制实现在直接磁场定向方案,使用定子磁链观测器,并在间接方案,基于电压矢量。在这两种方法中,都使用直流电压控制器来维持补偿器中必要的直流电平。通过计算机仿真和一台2马力样机的实验结果进行了分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Direct and indirect flux control of an isolated induction generator
This work presents an excitation control scheme for an induction generator using a PWM VAr compensator. The operation under variable speed conditions typical in wind drivers, the high performance, supported by the field oriented vector control and the total isolated operation, using a starting-up battery are the main features of this system. The vector control is implemented both in a direct field orientation scheme, using a stator flux observer, and in an indirect scheme, based on the voltage vector. In both methods, a DC voltage controller is used to maintain the necessary DC level in the compensator. The analysis is made by the aid of computer simulation and experimental results obtained from a 2 HP prototype.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信