非正弦和不平衡电压条件下的电流和电压检测

Xiaobin Zhang, Pan Zhang, Siyu Cheng, J. Duan, Hui Zhang
{"title":"非正弦和不平衡电压条件下的电流和电压检测","authors":"Xiaobin Zhang, Pan Zhang, Siyu Cheng, J. Duan, Hui Zhang","doi":"10.1109/PEAC.2014.7037959","DOIUrl":null,"url":null,"abstract":"The accurate and rapid detection of voltage and current in non-sinusoidal and unbalanced voltage condition is the prerequisite for grid power quality management and stable operation. Based on analyzing the vectors of the grid voltage and current, the rotating vector detection is carried out which can detect the voltage and current specified harmonic component and reactive and active current in non-sinusoidal and unbalanced voltage condition. The detection algorithm needs only the instantaneous value of voltage and current and no need the phase locking loop (PLL) to detect the voltage phase angle. The detection accuracy is not affected by the voltage frequency offset. The simulation results illustrate the accuracy of the rotating vector detection.","PeriodicalId":309780,"journal":{"name":"2014 International Power Electronics and Application Conference and Exposition","volume":"94 11","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The current and voltage detection under nonsinusoidal and unbalanced voltage condition\",\"authors\":\"Xiaobin Zhang, Pan Zhang, Siyu Cheng, J. Duan, Hui Zhang\",\"doi\":\"10.1109/PEAC.2014.7037959\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The accurate and rapid detection of voltage and current in non-sinusoidal and unbalanced voltage condition is the prerequisite for grid power quality management and stable operation. Based on analyzing the vectors of the grid voltage and current, the rotating vector detection is carried out which can detect the voltage and current specified harmonic component and reactive and active current in non-sinusoidal and unbalanced voltage condition. The detection algorithm needs only the instantaneous value of voltage and current and no need the phase locking loop (PLL) to detect the voltage phase angle. The detection accuracy is not affected by the voltage frequency offset. The simulation results illustrate the accuracy of the rotating vector detection.\",\"PeriodicalId\":309780,\"journal\":{\"name\":\"2014 International Power Electronics and Application Conference and Exposition\",\"volume\":\"94 11\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Power Electronics and Application Conference and Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEAC.2014.7037959\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Power Electronics and Application Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEAC.2014.7037959","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在非正弦和电压不平衡状态下准确、快速地检测电压电流是电网电能质量管理和稳定运行的前提。在分析电网电压和电流矢量的基础上,进行了旋转矢量检测,可以检测电压和电流在非正弦和电压不平衡状态下的指定谐波分量和无功电流和有功电流。该检测算法只需要电压和电流的瞬时值,不需要锁相环(PLL)来检测电压相角。检测精度不受电压频率偏移的影响。仿真结果验证了旋转矢量检测的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The current and voltage detection under nonsinusoidal and unbalanced voltage condition
The accurate and rapid detection of voltage and current in non-sinusoidal and unbalanced voltage condition is the prerequisite for grid power quality management and stable operation. Based on analyzing the vectors of the grid voltage and current, the rotating vector detection is carried out which can detect the voltage and current specified harmonic component and reactive and active current in non-sinusoidal and unbalanced voltage condition. The detection algorithm needs only the instantaneous value of voltage and current and no need the phase locking loop (PLL) to detect the voltage phase angle. The detection accuracy is not affected by the voltage frequency offset. The simulation results illustrate the accuracy of the rotating vector detection.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信