I. Antonova, S. Ceravolo, G. Corradi, G. Georgiev, V. Kozhuharov, M. Mitev, P. Valente, M. Raggi, L. Tsankov
{"title":"PADME带电粒子探测系统前端电子器件测试系统","authors":"I. Antonova, S. Ceravolo, G. Corradi, G. Georgiev, V. Kozhuharov, M. Mitev, P. Valente, M. Raggi, L. Tsankov","doi":"10.1109/ET.2017.8124360","DOIUrl":null,"url":null,"abstract":"The PADME charged particle detector system aims to detect positrons and electrons with efficiency better than 99 % and time resolution below 1 ns. The system hosts about 200 readout electronics channels whose operation has to be verified and commissioned. A custom based test system allowing performing qualitative check of the detector and the front-end electronics has been developed. The initial tests and the performance of the front-end electronics are described and discussed. Time resolution better than 400 ps was achieved.","PeriodicalId":127983,"journal":{"name":"2017 XXVI International Scientific Conference Electronics (ET)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A test system for the front-end electronics of the PADME charged particle detector system\",\"authors\":\"I. Antonova, S. Ceravolo, G. Corradi, G. Georgiev, V. Kozhuharov, M. Mitev, P. Valente, M. Raggi, L. Tsankov\",\"doi\":\"10.1109/ET.2017.8124360\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The PADME charged particle detector system aims to detect positrons and electrons with efficiency better than 99 % and time resolution below 1 ns. The system hosts about 200 readout electronics channels whose operation has to be verified and commissioned. A custom based test system allowing performing qualitative check of the detector and the front-end electronics has been developed. The initial tests and the performance of the front-end electronics are described and discussed. Time resolution better than 400 ps was achieved.\",\"PeriodicalId\":127983,\"journal\":{\"name\":\"2017 XXVI International Scientific Conference Electronics (ET)\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 XXVI International Scientific Conference Electronics (ET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ET.2017.8124360\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 XXVI International Scientific Conference Electronics (ET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ET.2017.8124360","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A test system for the front-end electronics of the PADME charged particle detector system
The PADME charged particle detector system aims to detect positrons and electrons with efficiency better than 99 % and time resolution below 1 ns. The system hosts about 200 readout electronics channels whose operation has to be verified and commissioned. A custom based test system allowing performing qualitative check of the detector and the front-end electronics has been developed. The initial tests and the performance of the front-end electronics are described and discussed. Time resolution better than 400 ps was achieved.