{"title":"[常规使用磁共振成像的障碍——一项评估核磁共振断层扫描的多中心研究的结果]。","authors":"A Oberstein,&nbsp;M Meves,&nbsp;S Bockenheimer,&nbsp;D Schlaps","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Within the framework of this study, the factors that impair the value of MR scans were also investigated and analysed. It was found that artifacts occurred in a large number of examinations that exercised a negative effect on the results. Artifacts are particularly seen in the thorax (54%) and upper abdomen (57%), but they have also been reported in 23% of the CNS examinations. The sources of such artifacts were mainly movements in the investigated layer, whereas other causes were negligible. In the 21,633 examined patients no undesirable effects caused by the examination were noted that would have impaired the patient or the course of the study. On an average, 88% of the examinations were performed with normal tolerance of the examination. In the remaining cases there was motor unrest or claustrophobia requiring special measures, thus hampering the course of the examination.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"10 1","pages":"10-6"},"PeriodicalIF":0.0000,"publicationDate":"1990-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Obstacles to the routine use of magnetic resonance imaging--results of a multicenter study for evaluating nuclear magnetic resonance tomography].\",\"authors\":\"A Oberstein,&nbsp;M Meves,&nbsp;S Bockenheimer,&nbsp;D Schlaps\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Within the framework of this study, the factors that impair the value of MR scans were also investigated and analysed. It was found that artifacts occurred in a large number of examinations that exercised a negative effect on the results. Artifacts are particularly seen in the thorax (54%) and upper abdomen (57%), but they have also been reported in 23% of the CNS examinations. The sources of such artifacts were mainly movements in the investigated layer, whereas other causes were negligible. In the 21,633 examined patients no undesirable effects caused by the examination were noted that would have impaired the patient or the course of the study. On an average, 88% of the examinations were performed with normal tolerance of the examination. In the remaining cases there was motor unrest or claustrophobia requiring special measures, thus hampering the course of the examination.</p>\",\"PeriodicalId\":77527,\"journal\":{\"name\":\"Digitale Bilddiagnostik\",\"volume\":\"10 1\",\"pages\":\"10-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Digitale Bilddiagnostik\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digitale Bilddiagnostik","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在本研究的框架内,影响磁共振扫描价值的因素也进行了调查和分析。结果发现,在大量对结果产生负面影响的考试中出现了伪影。伪影主要见于胸部(54%)和上腹部(57%),但也有23%的中枢神经系统检查报告有伪影。这些伪影的来源主要是被调查层的运动,而其他原因可以忽略不计。在接受检查的21,633名患者中,没有发现检查造成的不良影响,可能会损害患者或研究过程。平均88%的检查是在正常的检查耐受性下进行的。在其余病例中,有运动不安或幽闭恐惧症,需要采取特殊措施,从而妨碍了检查过程。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Obstacles to the routine use of magnetic resonance imaging--results of a multicenter study for evaluating nuclear magnetic resonance tomography].

Within the framework of this study, the factors that impair the value of MR scans were also investigated and analysed. It was found that artifacts occurred in a large number of examinations that exercised a negative effect on the results. Artifacts are particularly seen in the thorax (54%) and upper abdomen (57%), but they have also been reported in 23% of the CNS examinations. The sources of such artifacts were mainly movements in the investigated layer, whereas other causes were negligible. In the 21,633 examined patients no undesirable effects caused by the examination were noted that would have impaired the patient or the course of the study. On an average, 88% of the examinations were performed with normal tolerance of the examination. In the remaining cases there was motor unrest or claustrophobia requiring special measures, thus hampering the course of the examination.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信