{"title":"用于电能质量研究的新型时域电弧炉模型","authors":"D. Bhonsle, R. Kelkar","doi":"10.1109/IICPE.2014.7115761","DOIUrl":null,"url":null,"abstract":"Power quality is becoming a more concern of today's power system engineer due to rapid growth of non-linear loads in distribution network. Electric arc furnace (EAF) is one of the typical industrial non-linear loads responsible for deteriorating the power quality in the distribution network by-introducing harmonics, propagating voltage flicker and causing unbalance-in voltages and currents. Hence electric arc furnace model is needed to study and to analyze the power quality in the distribution network. This paper presents a new time domain model of electric arc furnace to study power quality problems. The proposed model is a combination of two previous EAF models called-Exponential and hyperbolic model-using transition functions. The functioning of the proposed model has been validated by comparing its performance characteristics with the existing Cassie-Mayr EAF model. Simulation carried out in SIMULINK/MATLAB environment.","PeriodicalId":206767,"journal":{"name":"2014 IEEE 6th India International Conference on Power Electronics (IICPE)","volume":"82 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"New time domain electric arc furnace model for power quality study\",\"authors\":\"D. Bhonsle, R. Kelkar\",\"doi\":\"10.1109/IICPE.2014.7115761\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power quality is becoming a more concern of today's power system engineer due to rapid growth of non-linear loads in distribution network. Electric arc furnace (EAF) is one of the typical industrial non-linear loads responsible for deteriorating the power quality in the distribution network by-introducing harmonics, propagating voltage flicker and causing unbalance-in voltages and currents. Hence electric arc furnace model is needed to study and to analyze the power quality in the distribution network. This paper presents a new time domain model of electric arc furnace to study power quality problems. The proposed model is a combination of two previous EAF models called-Exponential and hyperbolic model-using transition functions. The functioning of the proposed model has been validated by comparing its performance characteristics with the existing Cassie-Mayr EAF model. Simulation carried out in SIMULINK/MATLAB environment.\",\"PeriodicalId\":206767,\"journal\":{\"name\":\"2014 IEEE 6th India International Conference on Power Electronics (IICPE)\",\"volume\":\"82 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE 6th India International Conference on Power Electronics (IICPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IICPE.2014.7115761\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE 6th India International Conference on Power Electronics (IICPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IICPE.2014.7115761","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

由于配电网中非线性负荷的快速增长,电能质量成为当今电力系统工程师越来越关注的问题。电弧炉是一种典型的工业非线性负荷,它通过引入谐波、传播电压闪变和引起电压电流不平衡而使配电网的电能质量恶化。因此,需要建立电弧炉模型来研究和分析配电网中的电能质量。提出了一种新的电弧炉时域模型,用于研究电弧炉电能质量问题。提出的模型是使用过渡函数的两种EAF模型(指数模型和双曲模型)的组合。通过与现有Cassie-Mayr EAF模型的性能特征比较,验证了该模型的功能。仿真在SIMULINK/MATLAB环境下进行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
New time domain electric arc furnace model for power quality study
Power quality is becoming a more concern of today's power system engineer due to rapid growth of non-linear loads in distribution network. Electric arc furnace (EAF) is one of the typical industrial non-linear loads responsible for deteriorating the power quality in the distribution network by-introducing harmonics, propagating voltage flicker and causing unbalance-in voltages and currents. Hence electric arc furnace model is needed to study and to analyze the power quality in the distribution network. This paper presents a new time domain model of electric arc furnace to study power quality problems. The proposed model is a combination of two previous EAF models called-Exponential and hyperbolic model-using transition functions. The functioning of the proposed model has been validated by comparing its performance characteristics with the existing Cassie-Mayr EAF model. Simulation carried out in SIMULINK/MATLAB environment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信