硫化氢对钎焊接头的腐蚀

P. Wingert, C. Leung
{"title":"硫化氢对钎焊接头的腐蚀","authors":"P. Wingert, C. Leung","doi":"10.1109/HOLM.1989.77921","DOIUrl":null,"url":null,"abstract":"The early field failure of some motor control contactors due to the separation of the contacts from the copper arms to which they had been brazed was investigated. All of the failed devices were from geographical areas where the temperature and humidity were high and where there was a local source of sulfurous gases. Corrosion of the contact assemblies in the area of their braze joints by sulfur was identified as the cause of the premature failures. A laboratory test was used to evaluate the effectiveness of different assembly modifications in minimizing the corrosive attack by hydrogen sulfide. Silver plating was ineffective in protecting the braze joint from corrosion. Changing the braze alloy to one having a substantial zinc content was found to effectively impede the corrosive attack of the braze joint area and thus would be expected to increase the life of the devices in corrosive sulfurous environments.<<ETX>>","PeriodicalId":441734,"journal":{"name":"Proceedings of the Thirty Fifth Meeting of the IEEE Holm Conference on Electrical Contacts","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Corrosion of braze joints by hydrogen sulfide\",\"authors\":\"P. Wingert, C. Leung\",\"doi\":\"10.1109/HOLM.1989.77921\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The early field failure of some motor control contactors due to the separation of the contacts from the copper arms to which they had been brazed was investigated. All of the failed devices were from geographical areas where the temperature and humidity were high and where there was a local source of sulfurous gases. Corrosion of the contact assemblies in the area of their braze joints by sulfur was identified as the cause of the premature failures. A laboratory test was used to evaluate the effectiveness of different assembly modifications in minimizing the corrosive attack by hydrogen sulfide. Silver plating was ineffective in protecting the braze joint from corrosion. Changing the braze alloy to one having a substantial zinc content was found to effectively impede the corrosive attack of the braze joint area and thus would be expected to increase the life of the devices in corrosive sulfurous environments.<<ETX>>\",\"PeriodicalId\":441734,\"journal\":{\"name\":\"Proceedings of the Thirty Fifth Meeting of the IEEE Holm Conference on Electrical Contacts\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-09-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Thirty Fifth Meeting of the IEEE Holm Conference on Electrical Contacts\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HOLM.1989.77921\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Thirty Fifth Meeting of the IEEE Holm Conference on Electrical Contacts","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HOLM.1989.77921","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

研究了一些电机控制接触器由于与铜臂分离而导致的早期现场故障。所有故障设备都来自温度和湿度较高的地理区域,并且当地有含硫气体来源。接触组件在钎焊接头区域被硫腐蚀被确定为过早失效的原因。一项实验室测试用于评估不同的装配修改在最大限度地减少硫化氢腐蚀攻击方面的有效性。镀银对防止钎焊接头腐蚀无效。将钎焊合金改为含有大量锌的合金,可以有效地阻止钎焊接头区域的腐蚀,从而有望增加设备在腐蚀性含硫环境中的使用寿命。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Corrosion of braze joints by hydrogen sulfide
The early field failure of some motor control contactors due to the separation of the contacts from the copper arms to which they had been brazed was investigated. All of the failed devices were from geographical areas where the temperature and humidity were high and where there was a local source of sulfurous gases. Corrosion of the contact assemblies in the area of their braze joints by sulfur was identified as the cause of the premature failures. A laboratory test was used to evaluate the effectiveness of different assembly modifications in minimizing the corrosive attack by hydrogen sulfide. Silver plating was ineffective in protecting the braze joint from corrosion. Changing the braze alloy to one having a substantial zinc content was found to effectively impede the corrosive attack of the braze joint area and thus would be expected to increase the life of the devices in corrosive sulfurous environments.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信