用于高精度绝对相位检索的ML薄阵列SAR干涉传感器

F. Lombardini, P. Lombardo
{"title":"用于高精度绝对相位检索的ML薄阵列SAR干涉传感器","authors":"F. Lombardini, P. Lombardo","doi":"10.1109/NRC.1998.678012","DOIUrl":null,"url":null,"abstract":"The paper shows that the previously proposed three-element interferometric technique does not increase the phase ambiguity range in a deterministic manner. Namely there is still a probability that catastrophic phase errors of multiples of 2/spl pi/ are present, depending on the signal-to-noise power ratio, the number of looks and the extension of the required ambiguity range. After showing that a full array with the same unambiguous range magnification is much more robust, a thinned array interferometer is proposed. This is shown to have good performance as phase unwrapping and error standard deviation and sensibly reduced costs.","PeriodicalId":432418,"journal":{"name":"Proceedings of the 1998 IEEE Radar Conference, RADARCON'98. Challenges in Radar Systems and Solutions (Cat. No.98CH36197)","volume":"256O 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A ML thinned array SAR interferometric sensor for high accuracy absolute phase retrieval\",\"authors\":\"F. Lombardini, P. Lombardo\",\"doi\":\"10.1109/NRC.1998.678012\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper shows that the previously proposed three-element interferometric technique does not increase the phase ambiguity range in a deterministic manner. Namely there is still a probability that catastrophic phase errors of multiples of 2/spl pi/ are present, depending on the signal-to-noise power ratio, the number of looks and the extension of the required ambiguity range. After showing that a full array with the same unambiguous range magnification is much more robust, a thinned array interferometer is proposed. This is shown to have good performance as phase unwrapping and error standard deviation and sensibly reduced costs.\",\"PeriodicalId\":432418,\"journal\":{\"name\":\"Proceedings of the 1998 IEEE Radar Conference, RADARCON'98. Challenges in Radar Systems and Solutions (Cat. No.98CH36197)\",\"volume\":\"256O 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-05-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 1998 IEEE Radar Conference, RADARCON'98. Challenges in Radar Systems and Solutions (Cat. No.98CH36197)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NRC.1998.678012\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1998 IEEE Radar Conference, RADARCON'98. Challenges in Radar Systems and Solutions (Cat. No.98CH36197)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NRC.1998.678012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文表明,先前提出的三元干涉技术并不能确定地增加相位模糊范围。也就是说,仍然有可能存在2/spl pi/倍数的灾难性相位误差,这取决于信噪比、外观数量和所需模糊范围的扩展。在证明具有相同无二义范围放大倍率的全阵列干涉仪鲁棒性更强后,提出了一种薄阵列干涉仪。结果表明,该方法具有良好的相位展开性能和误差标准偏差,显著降低了成本。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A ML thinned array SAR interferometric sensor for high accuracy absolute phase retrieval
The paper shows that the previously proposed three-element interferometric technique does not increase the phase ambiguity range in a deterministic manner. Namely there is still a probability that catastrophic phase errors of multiples of 2/spl pi/ are present, depending on the signal-to-noise power ratio, the number of looks and the extension of the required ambiguity range. After showing that a full array with the same unambiguous range magnification is much more robust, a thinned array interferometer is proposed. This is shown to have good performance as phase unwrapping and error standard deviation and sensibly reduced costs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信