{"title":"额外的死区通风。","authors":"J Vávra,&nbsp;V Smejkal","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The authors studied the question of the completeness of ventilation of an additional dead space in the form of a tube 3 cm in diameter and with a volume of 600 ml. Seven young volunteers were examined while breathing with and without the tube, seated at rest and during a two-grade exercise load on a bicycle ergometer. The criterion of ventilation of the tube was enlargement of the dead space by 600 ml during breathing through the tube. The functional dead space was always calculated from the tidal volume and the CO2 concentration in mixed expired air and in an end-tidal sample, using the Bohr equation. In every case, the tube was found to be completely ventilated by breathing, both under resting conditions and during exercise. In breathing during the bicycle exercise, the ratio of the functional dead space to tidal volume fell from 0.3 to 0.19 and a similar decrease was recorded in breathing through the tube.</p>","PeriodicalId":20547,"journal":{"name":"Physiologia Bohemoslovaca","volume":"39 5","pages":"443-7"},"PeriodicalIF":0.0000,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ventilation of an additional dead space.\",\"authors\":\"J Vávra,&nbsp;V Smejkal\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The authors studied the question of the completeness of ventilation of an additional dead space in the form of a tube 3 cm in diameter and with a volume of 600 ml. Seven young volunteers were examined while breathing with and without the tube, seated at rest and during a two-grade exercise load on a bicycle ergometer. The criterion of ventilation of the tube was enlargement of the dead space by 600 ml during breathing through the tube. The functional dead space was always calculated from the tidal volume and the CO2 concentration in mixed expired air and in an end-tidal sample, using the Bohr equation. In every case, the tube was found to be completely ventilated by breathing, both under resting conditions and during exercise. In breathing during the bicycle exercise, the ratio of the functional dead space to tidal volume fell from 0.3 to 0.19 and a similar decrease was recorded in breathing through the tube.</p>\",\"PeriodicalId\":20547,\"journal\":{\"name\":\"Physiologia Bohemoslovaca\",\"volume\":\"39 5\",\"pages\":\"443-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physiologia Bohemoslovaca\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiologia Bohemoslovaca","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

作者研究了一个直径3厘米、体积为600毫升的管子形式的额外死空间的通气完整性问题。7名年轻志愿者在有和没有管子的情况下呼吸,休息时坐着,在自行车测力仪上进行两级运动负荷。插管通气的标准是通过插管呼吸时死腔扩大600ml。功能死区通常由潮汐体积和混合过期空气和潮汐末样品中的CO2浓度计算,使用玻尔方程。在每一个案例中,无论是在休息条件下还是在运动中,管子都被发现是完全通过呼吸通气的。在自行车运动时的呼吸中,功能性死区与潮气量之比从0.3下降到0.19,通过管道呼吸时也有类似的下降。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Ventilation of an additional dead space.

The authors studied the question of the completeness of ventilation of an additional dead space in the form of a tube 3 cm in diameter and with a volume of 600 ml. Seven young volunteers were examined while breathing with and without the tube, seated at rest and during a two-grade exercise load on a bicycle ergometer. The criterion of ventilation of the tube was enlargement of the dead space by 600 ml during breathing through the tube. The functional dead space was always calculated from the tidal volume and the CO2 concentration in mixed expired air and in an end-tidal sample, using the Bohr equation. In every case, the tube was found to be completely ventilated by breathing, both under resting conditions and during exercise. In breathing during the bicycle exercise, the ratio of the functional dead space to tidal volume fell from 0.3 to 0.19 and a similar decrease was recorded in breathing through the tube.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信