{"title":"用硅光电倍增管测量CY5荧光","authors":"M. F. Santangelo, S. L. Cono, P. Vasquez, G. Fallica, S. Conoci, A. Busacca, R. Pagano, E. Sciuto, S. Lombardo, S. Libertino","doi":"10.1109/BioCAS.2014.6981718","DOIUrl":null,"url":null,"abstract":"This paper presents an efficient optical biosensor set up for a low-level light detection, using fluorescent dyes and a novel Si-based detector. Fluorescence emitted by a traditional fluorophore, CY5, widely used as optical label in DNA microarrays, was detected using a 25 pixels Silicon photomultiplier (SiPM), a device formed by avalanche diodes operating in Geiger mode, in parallel connections. We measured the fluorescence current in different deposition (fluorophore concentration; solvent; salt concentration) and operation (angle of analysis, optical laser power, device gain) conditions. The characterization of DNA samples labeled with CY5 is also reported to demonstrate the detector potentiality to replace traditional optical readers commonly used in commercial devices.","PeriodicalId":414575,"journal":{"name":"2014 IEEE Biomedical Circuits and Systems Conference (BioCAS) Proceedings","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"CY5 fluorescence measured with silicon photomultipliers\",\"authors\":\"M. F. Santangelo, S. L. Cono, P. Vasquez, G. Fallica, S. Conoci, A. Busacca, R. Pagano, E. Sciuto, S. Lombardo, S. Libertino\",\"doi\":\"10.1109/BioCAS.2014.6981718\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an efficient optical biosensor set up for a low-level light detection, using fluorescent dyes and a novel Si-based detector. Fluorescence emitted by a traditional fluorophore, CY5, widely used as optical label in DNA microarrays, was detected using a 25 pixels Silicon photomultiplier (SiPM), a device formed by avalanche diodes operating in Geiger mode, in parallel connections. We measured the fluorescence current in different deposition (fluorophore concentration; solvent; salt concentration) and operation (angle of analysis, optical laser power, device gain) conditions. The characterization of DNA samples labeled with CY5 is also reported to demonstrate the detector potentiality to replace traditional optical readers commonly used in commercial devices.\",\"PeriodicalId\":414575,\"journal\":{\"name\":\"2014 IEEE Biomedical Circuits and Systems Conference (BioCAS) Proceedings\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE Biomedical Circuits and Systems Conference (BioCAS) Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BioCAS.2014.6981718\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Biomedical Circuits and Systems Conference (BioCAS) Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BioCAS.2014.6981718","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

本文介绍了一种利用荧光染料和新型硅基探测器建立的用于低强度光检测的高效光学生物传感器。传统荧光团CY5发出的荧光,广泛用于DNA微阵列的光学标记,使用25像素硅光电倍增管(SiPM)检测,SiPM是由雪崩二极管在盖革模式下并联连接形成的器件。我们测量了不同沉积条件下的荧光电流(荧光团浓度;溶剂;盐浓度)和操作(分析角度、光学激光功率、器件增益)条件。用CY5标记的DNA样品的表征也被报道证明了检测器取代商业设备中常用的传统光学读取器的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
CY5 fluorescence measured with silicon photomultipliers
This paper presents an efficient optical biosensor set up for a low-level light detection, using fluorescent dyes and a novel Si-based detector. Fluorescence emitted by a traditional fluorophore, CY5, widely used as optical label in DNA microarrays, was detected using a 25 pixels Silicon photomultiplier (SiPM), a device formed by avalanche diodes operating in Geiger mode, in parallel connections. We measured the fluorescence current in different deposition (fluorophore concentration; solvent; salt concentration) and operation (angle of analysis, optical laser power, device gain) conditions. The characterization of DNA samples labeled with CY5 is also reported to demonstrate the detector potentiality to replace traditional optical readers commonly used in commercial devices.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信