{"title":"GECAM卫星伽玛射线探测器标定装置研究","authors":"Zhou Pengyue, An Zhenghua, Wu Jinjie, Bai Zhanguo, Guo Siming","doi":"10.1109/ICEMI46757.2019.9101633","DOIUrl":null,"url":null,"abstract":"In order to meet the ground calibration requirements of Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) satellite gamma ray detector (GRD), two sets of single-energy x-ray calibration devices were established in China Metrology Institute (Changping). One set is a single crystal calibration device, and LiF crystal can realize continuous emission of (8.1-37.9) keV single-energy X-ray; The other set is a dual crystal calibration device. Si220 crystal and Si551 crystal can realize continuous light emission of single energy x-ray in the energy range of (38-160) keV. The X-ray energy spectrum, energy resolution and energy response of the calibration device were studied by standard high-purity germanium detectors. The test results show that the energy range of the calibration device is: (8-160) keV; monochromaticity: energy resolution 3.1%@8.1keV, 10.2%@79.9keV; monochromatic luminous flux 649cts/s@38. 0keV,678cts/s@79.9keV,298cts/s@121.8keV; monochromatic light ratio 96%@38.0keV, 97%@79.9keV, 96%@121.8keV. Combined with the actual test results of the energy point of the GRD, it indicates that the calibration device can meet the calibration requirements of the GRD.","PeriodicalId":419168,"journal":{"name":"2019 14th IEEE International Conference on Electronic Measurement & Instruments (ICEMI)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Research on calibration device of GECAM satellite gamma ray detector\",\"authors\":\"Zhou Pengyue, An Zhenghua, Wu Jinjie, Bai Zhanguo, Guo Siming\",\"doi\":\"10.1109/ICEMI46757.2019.9101633\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to meet the ground calibration requirements of Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) satellite gamma ray detector (GRD), two sets of single-energy x-ray calibration devices were established in China Metrology Institute (Changping). One set is a single crystal calibration device, and LiF crystal can realize continuous emission of (8.1-37.9) keV single-energy X-ray; The other set is a dual crystal calibration device. Si220 crystal and Si551 crystal can realize continuous light emission of single energy x-ray in the energy range of (38-160) keV. The X-ray energy spectrum, energy resolution and energy response of the calibration device were studied by standard high-purity germanium detectors. The test results show that the energy range of the calibration device is: (8-160) keV; monochromaticity: energy resolution 3.1%@8.1keV, 10.2%@79.9keV; monochromatic luminous flux 649cts/s@38. 0keV,678cts/s@79.9keV,298cts/s@121.8keV; monochromatic light ratio 96%@38.0keV, 97%@79.9keV, 96%@121.8keV. Combined with the actual test results of the energy point of the GRD, it indicates that the calibration device can meet the calibration requirements of the GRD.\",\"PeriodicalId\":419168,\"journal\":{\"name\":\"2019 14th IEEE International Conference on Electronic Measurement & Instruments (ICEMI)\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 14th IEEE International Conference on Electronic Measurement & Instruments (ICEMI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEMI46757.2019.9101633\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 14th IEEE International Conference on Electronic Measurement & Instruments (ICEMI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEMI46757.2019.9101633","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

为满足引力波高能电磁对应物全天监测(GECAM)卫星伽马射线探测器(GRD)地面标定要求,在中国计量科学研究院(昌平)建立了两套单能x射线标定装置。一套为单晶校准装置,liff晶体可实现连续发射(8.1-37.9)keV单能x射线;另一套是双晶校准装置。Si220晶体和Si551晶体可以实现(38-160)keV能量范围内单能量x射线的连续发光。采用标准高纯锗探测器对标定装置的x射线能谱、能量分辨率和能量响应进行了研究。试验结果表明,该标定装置的能量范围为:(8 ~ 160)keV;单色性:能量分辨率3.1%@8.1keV, 10.2%@79.9keV;单色光通量649cts/s@38。678年0 kev cts / s@79.9keV, 298 cts / s@121.8keV;单色光比96%@38.0keV, 97%@79.9keV, 96%@121.8keV。结合GRD能量点的实际测试结果,表明该标定装置能够满足GRD的标定要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Research on calibration device of GECAM satellite gamma ray detector
In order to meet the ground calibration requirements of Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) satellite gamma ray detector (GRD), two sets of single-energy x-ray calibration devices were established in China Metrology Institute (Changping). One set is a single crystal calibration device, and LiF crystal can realize continuous emission of (8.1-37.9) keV single-energy X-ray; The other set is a dual crystal calibration device. Si220 crystal and Si551 crystal can realize continuous light emission of single energy x-ray in the energy range of (38-160) keV. The X-ray energy spectrum, energy resolution and energy response of the calibration device were studied by standard high-purity germanium detectors. The test results show that the energy range of the calibration device is: (8-160) keV; monochromaticity: energy resolution 3.1%@8.1keV, 10.2%@79.9keV; monochromatic luminous flux 649cts/s@38. 0keV,678cts/s@79.9keV,298cts/s@121.8keV; monochromatic light ratio 96%@38.0keV, 97%@79.9keV, 96%@121.8keV. Combined with the actual test results of the energy point of the GRD, it indicates that the calibration device can meet the calibration requirements of the GRD.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信