局部放电源的混合辐射测量定位

R. Duarte, J. Villanueva, J. D. S. de Souza Neto, E. Macedo, R. P. de Medeiros
{"title":"局部放电源的混合辐射测量定位","authors":"R. Duarte, J. Villanueva, J. D. S. de Souza Neto, E. Macedo, R. P. de Medeiros","doi":"10.1109/INSCIT.2019.8868698","DOIUrl":null,"url":null,"abstract":"One way to diagnose the wear of electrical equipments is to identify the occurrence of partial discharges. From the detection of partial discharges, the maintenance of defective equipment can be programmed. Thus, the reliability of the system is increased and the chances of interruption decrease. Additionally, the information provided by partial discharge signals can be used to estimate the location of the source. In this work, we present a hybrid radiometric localization based on the energy and time of arrival of these signals. Using a two-dimensional ray tracing simulation model loaded with the map of a high voltage substation, this new technique was compared with two techniques based on the difference of the time-of-arrival of the signal at different receivers. Despite the reduced complexity, the hybrid technique has lower performance than those based on arrival times.","PeriodicalId":246490,"journal":{"name":"2019 4th International Symposium on Instrumentation Systems, Circuits and Transducers (INSCIT)","volume":"148 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Hybrid Radiometric Location of Partial Discharge Sources\",\"authors\":\"R. Duarte, J. Villanueva, J. D. S. de Souza Neto, E. Macedo, R. P. de Medeiros\",\"doi\":\"10.1109/INSCIT.2019.8868698\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"One way to diagnose the wear of electrical equipments is to identify the occurrence of partial discharges. From the detection of partial discharges, the maintenance of defective equipment can be programmed. Thus, the reliability of the system is increased and the chances of interruption decrease. Additionally, the information provided by partial discharge signals can be used to estimate the location of the source. In this work, we present a hybrid radiometric localization based on the energy and time of arrival of these signals. Using a two-dimensional ray tracing simulation model loaded with the map of a high voltage substation, this new technique was compared with two techniques based on the difference of the time-of-arrival of the signal at different receivers. Despite the reduced complexity, the hybrid technique has lower performance than those based on arrival times.\",\"PeriodicalId\":246490,\"journal\":{\"name\":\"2019 4th International Symposium on Instrumentation Systems, Circuits and Transducers (INSCIT)\",\"volume\":\"148 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 4th International Symposium on Instrumentation Systems, Circuits and Transducers (INSCIT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INSCIT.2019.8868698\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 4th International Symposium on Instrumentation Systems, Circuits and Transducers (INSCIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INSCIT.2019.8868698","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

识别局部放电的发生是诊断电气设备磨损的一种方法。通过对局部放电的检测,可以对有缺陷设备的维护进行编程。因此,提高了系统的可靠性,减少了中断的机会。此外,局部放电信号提供的信息可用于估计源的位置。在这项工作中,我们提出了一种基于这些信号到达的能量和时间的混合辐射定位。利用加载高压变电所图的二维射线追踪仿真模型,根据信号在不同接收器处到达时间的差异,与两种技术进行了比较。尽管降低了复杂性,但混合技术的性能低于基于到达时间的技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Hybrid Radiometric Location of Partial Discharge Sources
One way to diagnose the wear of electrical equipments is to identify the occurrence of partial discharges. From the detection of partial discharges, the maintenance of defective equipment can be programmed. Thus, the reliability of the system is increased and the chances of interruption decrease. Additionally, the information provided by partial discharge signals can be used to estimate the location of the source. In this work, we present a hybrid radiometric localization based on the energy and time of arrival of these signals. Using a two-dimensional ray tracing simulation model loaded with the map of a high voltage substation, this new technique was compared with two techniques based on the difference of the time-of-arrival of the signal at different receivers. Despite the reduced complexity, the hybrid technique has lower performance than those based on arrival times.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信