用对氨基苯甲酮氧化偶联反应分光光度法测定盐酸苯肾上腺素

H. Ahmed
{"title":"用对氨基苯甲酮氧化偶联反应分光光度法测定盐酸苯肾上腺素","authors":"H. Ahmed","doi":"10.48112/bcs.v2i2.455","DOIUrl":null,"url":null,"abstract":"In this research, a rapid, simple and accurate spectrophotometric approach was described for the estimation of phenylephrine hydrochloride in the pure and in its drug forms. The suggested method was based on the oxidative coupling reaction of phenylephrine hydrochloride with p-aminobenzophenone using potassium periodate as an oxidant. A taupe-red dye was formed at room temperature and showed maximum absorption at 512 nm. The linearity of the standard calibration curve was compatible with Beer's law within the concentration range of 2.0-20 μg/mL with a determination coefficient (r2=0.9986). The apparent molar absorptivity and the sensitivity of Sandell's index were calculated and found to be in the values of 0.552x104 L/mol.cm. and 0.0368 μg/cm2, respectively. The nature of the resulting dye has been studied between phenylephrine hydrochloride to p-aminobenzophenoneand and it was equal to 1:1. The limits of detection (LOD) and quantification (LOQ) were estimated and found to be 0.0094 and 0.0313 μg/mL, respectively. A relative standard deviation and a relative error were also calculated and they will be in the range of 0.0715 to 0.0216 and -0.0479% to -0.0145%, respectively. The recommended procedure was applied to assay phenylephrine hydrochloride in drops and injection and no interferences were observed from the common additives found in the drugs.","PeriodicalId":176903,"journal":{"name":"Biomedicine and Chemical Sciences","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Spectrophotometric Estimation of Phenylephrine Hydrochloride via Oxidative Coupling Reaction with p-Aminobenzophenone\",\"authors\":\"H. Ahmed\",\"doi\":\"10.48112/bcs.v2i2.455\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this research, a rapid, simple and accurate spectrophotometric approach was described for the estimation of phenylephrine hydrochloride in the pure and in its drug forms. The suggested method was based on the oxidative coupling reaction of phenylephrine hydrochloride with p-aminobenzophenone using potassium periodate as an oxidant. A taupe-red dye was formed at room temperature and showed maximum absorption at 512 nm. The linearity of the standard calibration curve was compatible with Beer's law within the concentration range of 2.0-20 μg/mL with a determination coefficient (r2=0.9986). The apparent molar absorptivity and the sensitivity of Sandell's index were calculated and found to be in the values of 0.552x104 L/mol.cm. and 0.0368 μg/cm2, respectively. The nature of the resulting dye has been studied between phenylephrine hydrochloride to p-aminobenzophenoneand and it was equal to 1:1. The limits of detection (LOD) and quantification (LOQ) were estimated and found to be 0.0094 and 0.0313 μg/mL, respectively. A relative standard deviation and a relative error were also calculated and they will be in the range of 0.0715 to 0.0216 and -0.0479% to -0.0145%, respectively. The recommended procedure was applied to assay phenylephrine hydrochloride in drops and injection and no interferences were observed from the common additives found in the drugs.\",\"PeriodicalId\":176903,\"journal\":{\"name\":\"Biomedicine and Chemical Sciences\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedicine and Chemical Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.48112/bcs.v2i2.455\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedicine and Chemical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.48112/bcs.v2i2.455","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究建立了一种快速、简便、准确的分光光度法测定盐酸苯肾上腺素的纯度和剂型。该方法以高碘酸钾为氧化剂,以盐酸苯肾上腺素与对氨基苯甲酮为原料进行氧化偶联反应。在室温下形成灰褐色的染料,在512 nm处表现出最大的吸收。在2.0 ~ 20 μg/mL浓度范围内,标准校准曲线线性符合比尔定律,确定系数r2=0.9986。计算表观摩尔吸收率和桑德尔指数的灵敏度为0.552x104 L/mol.cm。0.0368 μg/cm2。研究了所得染料在盐酸苯肾上腺素与对氨基苯甲酮的比例为1:1时的性质。方法的检出限和定量限分别为0.0094和0.0313 μg/mL。计算了相对标准偏差和相对误差,其范围分别为0.0715 ~ 0.0216和-0.0479% ~ -0.0145%。将推荐的方法应用于盐酸苯肾上腺素滴剂和针剂的测定,没有发现药物中常见添加剂的干扰。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Spectrophotometric Estimation of Phenylephrine Hydrochloride via Oxidative Coupling Reaction with p-Aminobenzophenone
In this research, a rapid, simple and accurate spectrophotometric approach was described for the estimation of phenylephrine hydrochloride in the pure and in its drug forms. The suggested method was based on the oxidative coupling reaction of phenylephrine hydrochloride with p-aminobenzophenone using potassium periodate as an oxidant. A taupe-red dye was formed at room temperature and showed maximum absorption at 512 nm. The linearity of the standard calibration curve was compatible with Beer's law within the concentration range of 2.0-20 μg/mL with a determination coefficient (r2=0.9986). The apparent molar absorptivity and the sensitivity of Sandell's index were calculated and found to be in the values of 0.552x104 L/mol.cm. and 0.0368 μg/cm2, respectively. The nature of the resulting dye has been studied between phenylephrine hydrochloride to p-aminobenzophenoneand and it was equal to 1:1. The limits of detection (LOD) and quantification (LOQ) were estimated and found to be 0.0094 and 0.0313 μg/mL, respectively. A relative standard deviation and a relative error were also calculated and they will be in the range of 0.0715 to 0.0216 and -0.0479% to -0.0145%, respectively. The recommended procedure was applied to assay phenylephrine hydrochloride in drops and injection and no interferences were observed from the common additives found in the drugs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信