b超图像中颈总动脉壁定位用于初始化动脉壁跟踪方法

Jan Dorazil, K. Říha, M. Dutta
{"title":"b超图像中颈总动脉壁定位用于初始化动脉壁跟踪方法","authors":"Jan Dorazil, K. Říha, M. Dutta","doi":"10.1109/TSP.2019.8769077","DOIUrl":null,"url":null,"abstract":"Analysis of the movement of the common carotid artery (CCA) wall in ultrasound sequences can be used for diagnosis of many cardiovascular diseases. In this paper we introduce a method for localization of the CCA wall contour (approximated by a circle) inside an ultrasound image, which can be used in real-time applications for initialization of an artery wall tracking method. First we detect a rectangular region of interest (ROI) using a recently proposed method based on the Viola-Jones detector. Next we perform an exhaustive search over all possible circles inside the ROI. Circle which maximizes a particular criterion represents the final estimate. Experimental results on a dataset of 145 ultrasound images show that the method outperforms a reference method based on the Hough transform in terms of precision and misdetection rates.","PeriodicalId":399087,"journal":{"name":"2019 42nd International Conference on Telecommunications and Signal Processing (TSP)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Common Carotid Artery Wall Localization in B-mode Ultrasound Images for Initialization of Artery Wall Tracking Methods\",\"authors\":\"Jan Dorazil, K. Říha, M. Dutta\",\"doi\":\"10.1109/TSP.2019.8769077\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Analysis of the movement of the common carotid artery (CCA) wall in ultrasound sequences can be used for diagnosis of many cardiovascular diseases. In this paper we introduce a method for localization of the CCA wall contour (approximated by a circle) inside an ultrasound image, which can be used in real-time applications for initialization of an artery wall tracking method. First we detect a rectangular region of interest (ROI) using a recently proposed method based on the Viola-Jones detector. Next we perform an exhaustive search over all possible circles inside the ROI. Circle which maximizes a particular criterion represents the final estimate. Experimental results on a dataset of 145 ultrasound images show that the method outperforms a reference method based on the Hough transform in terms of precision and misdetection rates.\",\"PeriodicalId\":399087,\"journal\":{\"name\":\"2019 42nd International Conference on Telecommunications and Signal Processing (TSP)\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 42nd International Conference on Telecommunications and Signal Processing (TSP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TSP.2019.8769077\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 42nd International Conference on Telecommunications and Signal Processing (TSP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TSP.2019.8769077","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

超声序列对颈总动脉(CCA)壁运动的分析可用于许多心血管疾病的诊断。在本文中,我们介绍了一种定位超声图像内CCA管壁轮廓(用圆近似)的方法,该方法可用于初始化动脉管壁跟踪方法的实时应用。首先,我们使用最近提出的基于Viola-Jones检测器的方法检测感兴趣的矩形区域(ROI)。接下来,我们对ROI内所有可能的圆执行穷举搜索。使特定标准最大化的圆表示最终估计。145张超声图像数据集的实验结果表明,该方法在精度和误检率方面都优于基于霍夫变换的参考方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Common Carotid Artery Wall Localization in B-mode Ultrasound Images for Initialization of Artery Wall Tracking Methods
Analysis of the movement of the common carotid artery (CCA) wall in ultrasound sequences can be used for diagnosis of many cardiovascular diseases. In this paper we introduce a method for localization of the CCA wall contour (approximated by a circle) inside an ultrasound image, which can be used in real-time applications for initialization of an artery wall tracking method. First we detect a rectangular region of interest (ROI) using a recently proposed method based on the Viola-Jones detector. Next we perform an exhaustive search over all possible circles inside the ROI. Circle which maximizes a particular criterion represents the final estimate. Experimental results on a dataset of 145 ultrasound images show that the method outperforms a reference method based on the Hough transform in terms of precision and misdetection rates.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信