{"title":"牙水泥的研究。1. 采用冷冻扫描电镜(Cryo-SEM)和图像分析仪(image analyzer)获得了三种luting胶结物的核芯结构。","authors":"H Hosoda, T Yamada, M Nakajima, L Perinka","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The polished surfaces of three set dental cements for luting (zinc phosphate cement, polycarboxylate cement, and glass ionomer cement) were observed by cryo-SEM at a specimen temperature of -160 degrees C to prevent damage of the cement specimens and also the specimens were analyzed by EDX. Furthermore, the SEM composition images of the polished cement surface were transferred to an image analyzer to obtain the core/matrix area ratio of the set cements. 1. The polished surface of set dental cement could be clearly observed by cryo-SEM without damaging the cement specimens. 2. The image analyzer showed that the core/matrix area ratio of the zinc phosphate cement and the glass ionomer cement was approximately 2 to 8, whereas that of the polycarboxylate cement was approximately 3 to 7. 3. The elements detected in the zinc phosphate cement were Ca, Zn, Mg, Al, and P, in the polycarboxylate cement were Ca, Zn, Mg, Si, and Sr, and in the glass ionomer cement were Al and Si.</p>","PeriodicalId":77622,"journal":{"name":"Shika zairyo, kikai = Journal of the Japanese Society for Dental Materials and Devices","volume":"9 2","pages":"197-204"},"PeriodicalIF":0.0000,"publicationDate":"1990-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Study on dental cements. 1. The cored structure of three luting cements obtained by using Cryo-SEM and image analyzer].\",\"authors\":\"H Hosoda, T Yamada, M Nakajima, L Perinka\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The polished surfaces of three set dental cements for luting (zinc phosphate cement, polycarboxylate cement, and glass ionomer cement) were observed by cryo-SEM at a specimen temperature of -160 degrees C to prevent damage of the cement specimens and also the specimens were analyzed by EDX. Furthermore, the SEM composition images of the polished cement surface were transferred to an image analyzer to obtain the core/matrix area ratio of the set cements. 1. The polished surface of set dental cement could be clearly observed by cryo-SEM without damaging the cement specimens. 2. The image analyzer showed that the core/matrix area ratio of the zinc phosphate cement and the glass ionomer cement was approximately 2 to 8, whereas that of the polycarboxylate cement was approximately 3 to 7. 3. The elements detected in the zinc phosphate cement were Ca, Zn, Mg, Al, and P, in the polycarboxylate cement were Ca, Zn, Mg, Si, and Sr, and in the glass ionomer cement were Al and Si.</p>\",\"PeriodicalId\":77622,\"journal\":{\"name\":\"Shika zairyo, kikai = Journal of the Japanese Society for Dental Materials and Devices\",\"volume\":\"9 2\",\"pages\":\"197-204\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Shika zairyo, kikai = Journal of the Japanese Society for Dental Materials and Devices\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Shika zairyo, kikai = Journal of the Japanese Society for Dental Materials and Devices","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Study on dental cements. 1. The cored structure of three luting cements obtained by using Cryo-SEM and image analyzer].
The polished surfaces of three set dental cements for luting (zinc phosphate cement, polycarboxylate cement, and glass ionomer cement) were observed by cryo-SEM at a specimen temperature of -160 degrees C to prevent damage of the cement specimens and also the specimens were analyzed by EDX. Furthermore, the SEM composition images of the polished cement surface were transferred to an image analyzer to obtain the core/matrix area ratio of the set cements. 1. The polished surface of set dental cement could be clearly observed by cryo-SEM without damaging the cement specimens. 2. The image analyzer showed that the core/matrix area ratio of the zinc phosphate cement and the glass ionomer cement was approximately 2 to 8, whereas that of the polycarboxylate cement was approximately 3 to 7. 3. The elements detected in the zinc phosphate cement were Ca, Zn, Mg, Al, and P, in the polycarboxylate cement were Ca, Zn, Mg, Si, and Sr, and in the glass ionomer cement were Al and Si.