牙水泥的研究。1. 采用冷冻扫描电镜(Cryo-SEM)和图像分析仪(image analyzer)获得了三种luting胶结物的核芯结构。

H Hosoda, T Yamada, M Nakajima, L Perinka
{"title":"牙水泥的研究。1. 采用冷冻扫描电镜(Cryo-SEM)和图像分析仪(image analyzer)获得了三种luting胶结物的核芯结构。","authors":"H Hosoda,&nbsp;T Yamada,&nbsp;M Nakajima,&nbsp;L Perinka","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The polished surfaces of three set dental cements for luting (zinc phosphate cement, polycarboxylate cement, and glass ionomer cement) were observed by cryo-SEM at a specimen temperature of -160 degrees C to prevent damage of the cement specimens and also the specimens were analyzed by EDX. Furthermore, the SEM composition images of the polished cement surface were transferred to an image analyzer to obtain the core/matrix area ratio of the set cements. 1. The polished surface of set dental cement could be clearly observed by cryo-SEM without damaging the cement specimens. 2. The image analyzer showed that the core/matrix area ratio of the zinc phosphate cement and the glass ionomer cement was approximately 2 to 8, whereas that of the polycarboxylate cement was approximately 3 to 7. 3. The elements detected in the zinc phosphate cement were Ca, Zn, Mg, Al, and P, in the polycarboxylate cement were Ca, Zn, Mg, Si, and Sr, and in the glass ionomer cement were Al and Si.</p>","PeriodicalId":77622,"journal":{"name":"Shika zairyo, kikai = Journal of the Japanese Society for Dental Materials and Devices","volume":"9 2","pages":"197-204"},"PeriodicalIF":0.0000,"publicationDate":"1990-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Study on dental cements. 1. The cored structure of three luting cements obtained by using Cryo-SEM and image analyzer].\",\"authors\":\"H Hosoda,&nbsp;T Yamada,&nbsp;M Nakajima,&nbsp;L Perinka\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The polished surfaces of three set dental cements for luting (zinc phosphate cement, polycarboxylate cement, and glass ionomer cement) were observed by cryo-SEM at a specimen temperature of -160 degrees C to prevent damage of the cement specimens and also the specimens were analyzed by EDX. Furthermore, the SEM composition images of the polished cement surface were transferred to an image analyzer to obtain the core/matrix area ratio of the set cements. 1. The polished surface of set dental cement could be clearly observed by cryo-SEM without damaging the cement specimens. 2. The image analyzer showed that the core/matrix area ratio of the zinc phosphate cement and the glass ionomer cement was approximately 2 to 8, whereas that of the polycarboxylate cement was approximately 3 to 7. 3. The elements detected in the zinc phosphate cement were Ca, Zn, Mg, Al, and P, in the polycarboxylate cement were Ca, Zn, Mg, Si, and Sr, and in the glass ionomer cement were Al and Si.</p>\",\"PeriodicalId\":77622,\"journal\":{\"name\":\"Shika zairyo, kikai = Journal of the Japanese Society for Dental Materials and Devices\",\"volume\":\"9 2\",\"pages\":\"197-204\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Shika zairyo, kikai = Journal of the Japanese Society for Dental Materials and Devices\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Shika zairyo, kikai = Journal of the Japanese Society for Dental Materials and Devices","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

采用低温扫描电镜(cro - sem)观察了磷酸锌骨水泥、聚羧酸骨水泥和玻璃离子骨水泥在-160℃下的抛光表面,以防止骨水泥试样的损伤,并对样品进行了EDX分析。此外,将抛光水泥表面的SEM成分图像传输到图像分析仪,以获得固化水泥的核心/基质面积比。1. 在不损伤牙水泥试样的情况下,低温扫描电镜能清晰地观察到牙水泥的抛光表面。2. 图像分析仪显示,磷酸锌水泥和玻璃离聚体水泥的芯基面积比约为2 ~ 8,聚羧酸盐水泥的芯基面积比约为3 ~ 7。3.磷酸锌水泥中检测到的元素有Ca、Zn、Mg、Al和P,聚羧酸水泥中检测到的元素有Ca、Zn、Mg、Si和Sr,玻璃离子水泥中检测到的元素有Al和Si。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Study on dental cements. 1. The cored structure of three luting cements obtained by using Cryo-SEM and image analyzer].

The polished surfaces of three set dental cements for luting (zinc phosphate cement, polycarboxylate cement, and glass ionomer cement) were observed by cryo-SEM at a specimen temperature of -160 degrees C to prevent damage of the cement specimens and also the specimens were analyzed by EDX. Furthermore, the SEM composition images of the polished cement surface were transferred to an image analyzer to obtain the core/matrix area ratio of the set cements. 1. The polished surface of set dental cement could be clearly observed by cryo-SEM without damaging the cement specimens. 2. The image analyzer showed that the core/matrix area ratio of the zinc phosphate cement and the glass ionomer cement was approximately 2 to 8, whereas that of the polycarboxylate cement was approximately 3 to 7. 3. The elements detected in the zinc phosphate cement were Ca, Zn, Mg, Al, and P, in the polycarboxylate cement were Ca, Zn, Mg, Si, and Sr, and in the glass ionomer cement were Al and Si.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信