牙尖角对咀嚼功能适应的影响。

Aichi Gakuin Daigaku Shigakkai shi Pub Date : 1990-03-01
H Usami
{"title":"牙尖角对咀嚼功能适应的影响。","authors":"H Usami","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this study was to elucidate the adaptation in masticatory function by changing the cusp angle of the natural dentition of one person using a metal splint. During each experiment mandibular movements and EMG were recorded during a period of weeks. While chewing raisins as test food, mandibular movements as measured by the lower incisal point displacement were detected three-dimensionally using the Selspot system, and electrical activity of the masticatory muscles was picked up for the anterior temporal and masseter muscles, at the right and left using surface electrodes. The time schedule was composed of three terms: (1) before insertion of the splint, (2) for 20 days after insertion of the splint and then for 30 days after removal (Experiment-1), (3) for 14 days after reinsertion of the splint and then for 7 day after removal (Experiment-2). The measurements were done for the following 7 indices: (1) opening phase, (2) closing phase, (3) cycle time, (4) stopping phase (St), which is the period when the mandible was stationary during occlusal contact, (5) duration of EMG activity, (6) duration of EMG silence, (7) the period of EMG silence (IA), which is the period from the end of EMG activity to the end of the stopping phase. The following results were obtained 1) On changing the cusp angle, there was an increase in cycle time, closing phase, opening phase, duration of EMG activity, and duration of EMG silence, but the stopping phase was less than before insertion of the splint. These 6 indices showed a great variation and became irregular at first. 2) The irregularity of the masticatory function disappeared gradually, and then all indices approached the value before insertion of the splint from day 5 or day 20 at the latest. 3) Scarcely any reaction was detected in IA or in the ratio of cycle time and opening phase throughout the measurement period. 4) The indices of the reinsertion period (Experiment 2) approached the value before insertion more rapidly than the period of the insertion (Experiment-1). And the indices after removal quickly approached pre-insertion values. In short, the indices of the time factor of the masticatory function showed that the effect of changing cusp angle was handled as only disturbances. And once the first adaptation was completed, masticatory function responded more quickly to the same stimulus.(ABSTRACT TRUNCATED AT 400 WORDS)</p>","PeriodicalId":75458,"journal":{"name":"Aichi Gakuin Daigaku Shigakkai shi","volume":"28 1 Pt 2","pages":"483-97"},"PeriodicalIF":0.0000,"publicationDate":"1990-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Effects of cusp angle on the adaptation of masticatory function].\",\"authors\":\"H Usami\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The purpose of this study was to elucidate the adaptation in masticatory function by changing the cusp angle of the natural dentition of one person using a metal splint. During each experiment mandibular movements and EMG were recorded during a period of weeks. While chewing raisins as test food, mandibular movements as measured by the lower incisal point displacement were detected three-dimensionally using the Selspot system, and electrical activity of the masticatory muscles was picked up for the anterior temporal and masseter muscles, at the right and left using surface electrodes. The time schedule was composed of three terms: (1) before insertion of the splint, (2) for 20 days after insertion of the splint and then for 30 days after removal (Experiment-1), (3) for 14 days after reinsertion of the splint and then for 7 day after removal (Experiment-2). The measurements were done for the following 7 indices: (1) opening phase, (2) closing phase, (3) cycle time, (4) stopping phase (St), which is the period when the mandible was stationary during occlusal contact, (5) duration of EMG activity, (6) duration of EMG silence, (7) the period of EMG silence (IA), which is the period from the end of EMG activity to the end of the stopping phase. The following results were obtained 1) On changing the cusp angle, there was an increase in cycle time, closing phase, opening phase, duration of EMG activity, and duration of EMG silence, but the stopping phase was less than before insertion of the splint. These 6 indices showed a great variation and became irregular at first. 2) The irregularity of the masticatory function disappeared gradually, and then all indices approached the value before insertion of the splint from day 5 or day 20 at the latest. 3) Scarcely any reaction was detected in IA or in the ratio of cycle time and opening phase throughout the measurement period. 4) The indices of the reinsertion period (Experiment 2) approached the value before insertion more rapidly than the period of the insertion (Experiment-1). And the indices after removal quickly approached pre-insertion values. In short, the indices of the time factor of the masticatory function showed that the effect of changing cusp angle was handled as only disturbances. And once the first adaptation was completed, masticatory function responded more quickly to the same stimulus.(ABSTRACT TRUNCATED AT 400 WORDS)</p>\",\"PeriodicalId\":75458,\"journal\":{\"name\":\"Aichi Gakuin Daigaku Shigakkai shi\",\"volume\":\"28 1 Pt 2\",\"pages\":\"483-97\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Aichi Gakuin Daigaku Shigakkai shi\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Aichi Gakuin Daigaku Shigakkai shi","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是通过改变一个人使用金属夹板的自然牙列尖牙角来阐明咀嚼功能的适应性。在每次实验中,连续数周记录下颌运动和肌电图。在咀嚼葡萄干作为测试食物时,使用Selspot系统对下颌运动进行三维检测,通过下切点位移测量下颌运动,并使用表面电极采集右侧和左侧颞前部和咬肌的咀嚼肌电活动。时间安排由三个时间段组成:(1)夹板插入前,(2)夹板插入后20天,取出后30天(实验-1),(3)夹板重新插入后14天,取出后7天(实验-2)。测量了以下7个指标:(1)开启阶段,(2)关闭阶段,(3)循环时间,(4)停止阶段(St),即咬合接触时下颌骨静止的时间,(5)肌电活动持续时间,(6)肌电沉默持续时间,(7)肌电沉默周期(IA),即肌电活动结束到停止阶段结束的时间。结果表明:1)改变针尖角后,循环时间、闭合相、开启相、肌电活动持续时间、肌电沉默持续时间均有所增加,但停止相较置入夹板前有所减少。这6项指标变化较大,开始时呈不规则性。2)咀嚼功能的不规则性逐渐消失,最迟从第5天或第20天开始,各项指标逐渐接近插入夹板前的值。3)在整个测量周期内,IA或循环时间与开启相的比值几乎没有检测到任何反应。4)重新插入周期(实验2)的指标比插入周期(实验1)更接近插入前的值。删除后的指数很快接近插入前的值。总之,咀嚼功能的时间因子指标表明,尖角变化的影响仅被视为干扰。一旦第一次适应完成,咀嚼功能对同样的刺激反应更快。(摘要删节为400字)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Effects of cusp angle on the adaptation of masticatory function].

The purpose of this study was to elucidate the adaptation in masticatory function by changing the cusp angle of the natural dentition of one person using a metal splint. During each experiment mandibular movements and EMG were recorded during a period of weeks. While chewing raisins as test food, mandibular movements as measured by the lower incisal point displacement were detected three-dimensionally using the Selspot system, and electrical activity of the masticatory muscles was picked up for the anterior temporal and masseter muscles, at the right and left using surface electrodes. The time schedule was composed of three terms: (1) before insertion of the splint, (2) for 20 days after insertion of the splint and then for 30 days after removal (Experiment-1), (3) for 14 days after reinsertion of the splint and then for 7 day after removal (Experiment-2). The measurements were done for the following 7 indices: (1) opening phase, (2) closing phase, (3) cycle time, (4) stopping phase (St), which is the period when the mandible was stationary during occlusal contact, (5) duration of EMG activity, (6) duration of EMG silence, (7) the period of EMG silence (IA), which is the period from the end of EMG activity to the end of the stopping phase. The following results were obtained 1) On changing the cusp angle, there was an increase in cycle time, closing phase, opening phase, duration of EMG activity, and duration of EMG silence, but the stopping phase was less than before insertion of the splint. These 6 indices showed a great variation and became irregular at first. 2) The irregularity of the masticatory function disappeared gradually, and then all indices approached the value before insertion of the splint from day 5 or day 20 at the latest. 3) Scarcely any reaction was detected in IA or in the ratio of cycle time and opening phase throughout the measurement period. 4) The indices of the reinsertion period (Experiment 2) approached the value before insertion more rapidly than the period of the insertion (Experiment-1). And the indices after removal quickly approached pre-insertion values. In short, the indices of the time factor of the masticatory function showed that the effect of changing cusp angle was handled as only disturbances. And once the first adaptation was completed, masticatory function responded more quickly to the same stimulus.(ABSTRACT TRUNCATED AT 400 WORDS)

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信