{"title":"K6诊断系统的基础调查。3.带传感器通道装置的制作及其精度评价[j]。","authors":"E Aida, S Imamura, K Kurosu","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Unlabelled: </strong>An investigation was undertaken to evaluated the accuracy of Sensor Alley, a mandibular movement analyser: K6 Diagnostic System EX with a newly designed auxiliary apparatus.</p><p><strong>Results: </strong>1) The errors in the values of the standard Sensor Alley were 4.8 mm for the VER-coordinate, 5.0 mm for the AP-coordinate and 3.0 mm for LA-coordinate. 2) The errors of the AP-coordinate were bigger than those of the VER and LA-coordinates. 3) The errors in the values of the standard Sensor Alley fitted with a newly designed auxiliary apparatus were 0.9 mm for the VER-coordinate, 2.0 mm for the AP-coordinate and 1.1 mm for the LA-coordinate. 4) The results led to the conclusion that this newly designed auxiliary apparatus was useful for various studies on mandibular movement used with the K6 Diagnostic System EX.</p>","PeriodicalId":75458,"journal":{"name":"Aichi Gakuin Daigaku Shigakkai shi","volume":"28 3","pages":"797-802"},"PeriodicalIF":0.0000,"publicationDate":"1990-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Basic investigation using K6 diagnostic system. 3. Fabrication of the apparatus wearing a Sensor Alley and the evaluation of its accuracy].\",\"authors\":\"E Aida, S Imamura, K Kurosu\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Unlabelled: </strong>An investigation was undertaken to evaluated the accuracy of Sensor Alley, a mandibular movement analyser: K6 Diagnostic System EX with a newly designed auxiliary apparatus.</p><p><strong>Results: </strong>1) The errors in the values of the standard Sensor Alley were 4.8 mm for the VER-coordinate, 5.0 mm for the AP-coordinate and 3.0 mm for LA-coordinate. 2) The errors of the AP-coordinate were bigger than those of the VER and LA-coordinates. 3) The errors in the values of the standard Sensor Alley fitted with a newly designed auxiliary apparatus were 0.9 mm for the VER-coordinate, 2.0 mm for the AP-coordinate and 1.1 mm for the LA-coordinate. 4) The results led to the conclusion that this newly designed auxiliary apparatus was useful for various studies on mandibular movement used with the K6 Diagnostic System EX.</p>\",\"PeriodicalId\":75458,\"journal\":{\"name\":\"Aichi Gakuin Daigaku Shigakkai shi\",\"volume\":\"28 3\",\"pages\":\"797-802\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Aichi Gakuin Daigaku Shigakkai shi\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Aichi Gakuin Daigaku Shigakkai shi","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
未标记:进行了一项调查,以评估Sensor Alley的准确性,这是一种下颌运动分析仪:K6诊断系统EX与新设计的辅助设备。结果:1)标准Sensor Alley值在ver坐标下误差4.8 mm, ap坐标下误差5.0 mm, la坐标下误差3.0 mm。2) ap -坐标误差大于VER和la -坐标误差。3)安装新设计的辅助装置后,标准Sensor Alley的值误差为ver坐标0.9 mm, ap坐标2.0 mm, la坐标1.1 mm。4)结果表明,这种新设计的辅助器械可用于与K6诊断系统EX配合使用的各种下颌运动研究。
[Basic investigation using K6 diagnostic system. 3. Fabrication of the apparatus wearing a Sensor Alley and the evaluation of its accuracy].
Unlabelled: An investigation was undertaken to evaluated the accuracy of Sensor Alley, a mandibular movement analyser: K6 Diagnostic System EX with a newly designed auxiliary apparatus.
Results: 1) The errors in the values of the standard Sensor Alley were 4.8 mm for the VER-coordinate, 5.0 mm for the AP-coordinate and 3.0 mm for LA-coordinate. 2) The errors of the AP-coordinate were bigger than those of the VER and LA-coordinates. 3) The errors in the values of the standard Sensor Alley fitted with a newly designed auxiliary apparatus were 0.9 mm for the VER-coordinate, 2.0 mm for the AP-coordinate and 1.1 mm for the LA-coordinate. 4) The results led to the conclusion that this newly designed auxiliary apparatus was useful for various studies on mandibular movement used with the K6 Diagnostic System EX.