[5种电子测量装置的读数比较]。

K Shinoda, T Hoji, M Nakashima, I Sekine, Y Mukouyama
{"title":"[5种电子测量装置的读数比较]。","authors":"K Shinoda,&nbsp;T Hoji,&nbsp;M Nakashima,&nbsp;I Sekine,&nbsp;Y Mukouyama","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The root apex values given in the manufacturers' introductions of 5 electronic measuring devices were compared with the mean values measured by each device in the following cases: a) The tip of file was at the apical constriction in the experimental tooth model. b) The tip of file was between 0 mm and -2.0 mm from the root apex in the vital teeth and the pulpless teeth. In the experimental tooth model, when the tip of file was at the apical constriction, the mean values measured by each device except EM were lower than the root apex values given in the manufacturers' introductions of each device. In the case of the vital tooth, when the tip of file was between 0 mm and -2.0 mm from the root apex, the mean values measured by EM-S II and EM were similar to the values given in the manufacturers' introductions of these devices, but not to those obtained by the other devices. Measurements of the pulpless tooth by each device revealed mean values lower than the values given in manufacturers' introductions for the root apex.</p>","PeriodicalId":12643,"journal":{"name":"Gifu Shika Gakkai zasshi = The Journal of Gifu Dental Society","volume":"17 1","pages":"246-52"},"PeriodicalIF":0.0000,"publicationDate":"1990-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Comparisons of meter reading values in 5 electronic measuring devices].\",\"authors\":\"K Shinoda,&nbsp;T Hoji,&nbsp;M Nakashima,&nbsp;I Sekine,&nbsp;Y Mukouyama\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The root apex values given in the manufacturers' introductions of 5 electronic measuring devices were compared with the mean values measured by each device in the following cases: a) The tip of file was at the apical constriction in the experimental tooth model. b) The tip of file was between 0 mm and -2.0 mm from the root apex in the vital teeth and the pulpless teeth. In the experimental tooth model, when the tip of file was at the apical constriction, the mean values measured by each device except EM were lower than the root apex values given in the manufacturers' introductions of each device. In the case of the vital tooth, when the tip of file was between 0 mm and -2.0 mm from the root apex, the mean values measured by EM-S II and EM were similar to the values given in the manufacturers' introductions of these devices, but not to those obtained by the other devices. Measurements of the pulpless tooth by each device revealed mean values lower than the values given in manufacturers' introductions for the root apex.</p>\",\"PeriodicalId\":12643,\"journal\":{\"name\":\"Gifu Shika Gakkai zasshi = The Journal of Gifu Dental Society\",\"volume\":\"17 1\",\"pages\":\"246-52\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Gifu Shika Gakkai zasshi = The Journal of Gifu Dental Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gifu Shika Gakkai zasshi = The Journal of Gifu Dental Society","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

将5种电子测量装置的生产厂家介绍中给出的根尖测量值与各设备测量值的平均值在以下情况下进行比较:a)实验牙模型中锉尖处于根尖缩窄处。b)锉尖距活牙和无髓牙根尖0 ~ -2.0 mm。在实验牙模型中,当锉尖处于尖缩时,除EM外,各器械测量的平均值均低于各器械厂家介绍中给出的根尖值。在重要牙的情况下,当锉尖距离根尖0 mm至-2.0 mm之间时,EM- s II和EM测量的平均值与制造商介绍中给出的值相似,但与其他设备所获得的值不同。每个装置对无髓牙的测量结果显示,平均值低于制造商介绍的牙根尖值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Comparisons of meter reading values in 5 electronic measuring devices].

The root apex values given in the manufacturers' introductions of 5 electronic measuring devices were compared with the mean values measured by each device in the following cases: a) The tip of file was at the apical constriction in the experimental tooth model. b) The tip of file was between 0 mm and -2.0 mm from the root apex in the vital teeth and the pulpless teeth. In the experimental tooth model, when the tip of file was at the apical constriction, the mean values measured by each device except EM were lower than the root apex values given in the manufacturers' introductions of each device. In the case of the vital tooth, when the tip of file was between 0 mm and -2.0 mm from the root apex, the mean values measured by EM-S II and EM were similar to the values given in the manufacturers' introductions of these devices, but not to those obtained by the other devices. Measurements of the pulpless tooth by each device revealed mean values lower than the values given in manufacturers' introductions for the root apex.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信