{"title":"直流270V与直流28V电弧特性对比实验研究","authors":"Yaqi Liu, Xinglei Cui","doi":"10.1109/ICEPE-ST.2011.6122904","DOIUrl":null,"url":null,"abstract":"In order to fulfill the increasing need for high electric power and to decrease the weight of electrical equipments, the supply level must be increased and the electrical apparatus has to be upgraded accordingly. In our present work, experiments are carried out to compare the arc characteristics on break between DC 28V and DC 270V under the conditions of different current and transverse magnetic fields (TMF). The current is lower than 10A, and the flux density is below 100mT. Arc images are acquired with high speed cameras and arc voltage waveforms are obtained. Arc characteristics such as arc duration, extinction gap, displacement of arc root are analyzed. Experiment results show that under the same break power, TMF is more effective in arc inhibition under the condition of DC 270V compared with DC28V. The work can offer some guide for the design of arc extinction system for DC 270 V relays.","PeriodicalId":379448,"journal":{"name":"2011 1st International Conference on Electric Power Equipment - Switching Technology","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental research on the comparison of the arc characteristics between DC 270V and DC 28V\",\"authors\":\"Yaqi Liu, Xinglei Cui\",\"doi\":\"10.1109/ICEPE-ST.2011.6122904\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to fulfill the increasing need for high electric power and to decrease the weight of electrical equipments, the supply level must be increased and the electrical apparatus has to be upgraded accordingly. In our present work, experiments are carried out to compare the arc characteristics on break between DC 28V and DC 270V under the conditions of different current and transverse magnetic fields (TMF). The current is lower than 10A, and the flux density is below 100mT. Arc images are acquired with high speed cameras and arc voltage waveforms are obtained. Arc characteristics such as arc duration, extinction gap, displacement of arc root are analyzed. Experiment results show that under the same break power, TMF is more effective in arc inhibition under the condition of DC 270V compared with DC28V. The work can offer some guide for the design of arc extinction system for DC 270 V relays.\",\"PeriodicalId\":379448,\"journal\":{\"name\":\"2011 1st International Conference on Electric Power Equipment - Switching Technology\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 1st International Conference on Electric Power Equipment - Switching Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEPE-ST.2011.6122904\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 1st International Conference on Electric Power Equipment - Switching Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEPE-ST.2011.6122904","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了满足日益增长的高功率需求和减轻电气设备的重量,必须提高供电水平,并对电气设备进行相应的升级。本文通过实验比较了直流28V和直流270V在不同电流和横向磁场(TMF)条件下的断弧特性。电流小于10A,磁通密度小于100mT。利用高速摄像机采集电弧图像,得到电弧电压波形。分析了电弧持续时间、消弧间隙、电弧根部位移等电弧特性。实验结果表明,在相同断电流功率下,与DC28V相比,TMF在DC 270V条件下的抑弧效果更好。该工作对直流270v继电器消弧系统的设计具有一定的指导意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental research on the comparison of the arc characteristics between DC 270V and DC 28V
In order to fulfill the increasing need for high electric power and to decrease the weight of electrical equipments, the supply level must be increased and the electrical apparatus has to be upgraded accordingly. In our present work, experiments are carried out to compare the arc characteristics on break between DC 28V and DC 270V under the conditions of different current and transverse magnetic fields (TMF). The current is lower than 10A, and the flux density is below 100mT. Arc images are acquired with high speed cameras and arc voltage waveforms are obtained. Arc characteristics such as arc duration, extinction gap, displacement of arc root are analyzed. Experiment results show that under the same break power, TMF is more effective in arc inhibition under the condition of DC 270V compared with DC28V. The work can offer some guide for the design of arc extinction system for DC 270 V relays.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信