Y Endo, H Aoki, T Fujita, M Yamamura, N Takeuchi, K Kimoto, K Tamaki, Y Nagashima
{"title":"用签名仪显示线性测量记录精度的研究。","authors":"Y Endo, H Aoki, T Fujita, M Yamamura, N Takeuchi, K Kimoto, K Tamaki, Y Nagashima","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The recording accuracy of Sirognathograph (Siemens, West Germany) was conducted by means of an experimental apparatus. Diagrams of mandibular border movements in three dimensional directions were performed. The results showed the distortion was not recognized within 5 mm of primary condition in a subject, but slightly between 5 mm and 10 mm. In a distance of more than 15 mm, a considerable distortion was increased until at the maximum opening position.</p>","PeriodicalId":77633,"journal":{"name":"The Bulletin of the Kanagawa Dental College : BKDC","volume":"18 2","pages":"103-5"},"PeriodicalIF":0.0000,"publicationDate":"1990-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A study of recording accuracy in linear measurements displayed by sirognathograph.\",\"authors\":\"Y Endo, H Aoki, T Fujita, M Yamamura, N Takeuchi, K Kimoto, K Tamaki, Y Nagashima\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The recording accuracy of Sirognathograph (Siemens, West Germany) was conducted by means of an experimental apparatus. Diagrams of mandibular border movements in three dimensional directions were performed. The results showed the distortion was not recognized within 5 mm of primary condition in a subject, but slightly between 5 mm and 10 mm. In a distance of more than 15 mm, a considerable distortion was increased until at the maximum opening position.</p>\",\"PeriodicalId\":77633,\"journal\":{\"name\":\"The Bulletin of the Kanagawa Dental College : BKDC\",\"volume\":\"18 2\",\"pages\":\"103-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Bulletin of the Kanagawa Dental College : BKDC\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Bulletin of the Kanagawa Dental College : BKDC","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A study of recording accuracy in linear measurements displayed by sirognathograph.
The recording accuracy of Sirognathograph (Siemens, West Germany) was conducted by means of an experimental apparatus. Diagrams of mandibular border movements in three dimensional directions were performed. The results showed the distortion was not recognized within 5 mm of primary condition in a subject, but slightly between 5 mm and 10 mm. In a distance of more than 15 mm, a considerable distortion was increased until at the maximum opening position.