{"title":"基于混合可再生能源的外加电流阴极保护智能系统","authors":"C. A. Sibiya, K. Kusakana, B. Numbi","doi":"10.1109/OI.2018.8535796","DOIUrl":null,"url":null,"abstract":"The primary objective of this paper is to propose a system for Impressed Current Cathodic Protection running on renewable energy. Generally additional corrosion prevention based on sacrificial anodes, Impressed Current Cathodic Protection and Alternating Current mitigation are installed into underground/ buried pipelines to provide protection against accelerated corrosion to the part of the pipeline that becomes unprotected by a result of degraded coating and stray currents. In this research, studies to determine the amount of power required to shift the potential level of the buried pipeline will be outlined, this will clearly show the load profile of the structure to be protected and from there a hybrid system shall be designed and modelled. This document outlines the reason for hybrid powered Impressed Current Cathodic Protection, objectives of the research and how they will be achieved.","PeriodicalId":331140,"journal":{"name":"2018 Open Innovations Conference (OI)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Smart System for Impressed Current Cathodic Protection Running on Hybrid Renewable Energy\",\"authors\":\"C. A. Sibiya, K. Kusakana, B. Numbi\",\"doi\":\"10.1109/OI.2018.8535796\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The primary objective of this paper is to propose a system for Impressed Current Cathodic Protection running on renewable energy. Generally additional corrosion prevention based on sacrificial anodes, Impressed Current Cathodic Protection and Alternating Current mitigation are installed into underground/ buried pipelines to provide protection against accelerated corrosion to the part of the pipeline that becomes unprotected by a result of degraded coating and stray currents. In this research, studies to determine the amount of power required to shift the potential level of the buried pipeline will be outlined, this will clearly show the load profile of the structure to be protected and from there a hybrid system shall be designed and modelled. This document outlines the reason for hybrid powered Impressed Current Cathodic Protection, objectives of the research and how they will be achieved.\",\"PeriodicalId\":331140,\"journal\":{\"name\":\"2018 Open Innovations Conference (OI)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 Open Innovations Conference (OI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/OI.2018.8535796\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 Open Innovations Conference (OI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OI.2018.8535796","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文的主要目的是提出一种基于可再生能源的外加电流阴极保护系统。通常,在地下/埋地管道中安装基于牺牲阳极、外加电流阴极保护和交流电缓蚀剂的额外防腐蚀措施,以防止由于涂层退化和杂散电流而失去保护的管道部分加速腐蚀。在本研究中,将概述确定转移埋地管道潜在水平所需的功率量的研究,这将清楚地显示要保护的结构的负载概况,并从那里设计和建模混合系统。本文档概述了混合动力外加电流阴极保护的原因,研究的目标以及如何实现这些目标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Smart System for Impressed Current Cathodic Protection Running on Hybrid Renewable Energy
The primary objective of this paper is to propose a system for Impressed Current Cathodic Protection running on renewable energy. Generally additional corrosion prevention based on sacrificial anodes, Impressed Current Cathodic Protection and Alternating Current mitigation are installed into underground/ buried pipelines to provide protection against accelerated corrosion to the part of the pipeline that becomes unprotected by a result of degraded coating and stray currents. In this research, studies to determine the amount of power required to shift the potential level of the buried pipeline will be outlined, this will clearly show the load profile of the structure to be protected and from there a hybrid system shall be designed and modelled. This document outlines the reason for hybrid powered Impressed Current Cathodic Protection, objectives of the research and how they will be achieved.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信