变频和变气压下电晕局部放电特性的研究

A. Esfahani, S. Shahabi, G. Stone, B. Kordi
{"title":"变频和变气压下电晕局部放电特性的研究","authors":"A. Esfahani, S. Shahabi, G. Stone, B. Kordi","doi":"10.1109/EIC.2018.8481047","DOIUrl":null,"url":null,"abstract":"The rapid growth of electric apparatus in the more electric aircraft (MEA) causes the necessity to step up the electrical power. This, in turn, requires to a higher voltage which increases the electrical stress on insulation system. This can cause partial discharge (PD) in aircraft insulation system. Also, the aircraft generator provides electrical power with variable frequency. The insulation system of aircraft generator experiences different range of air pressure levels under variable voltage frequency. There is an interest on partial discharge detection under this condition. This paper presents the experimental tests that have been conducted to study the impact of voltage frequency and air pressure on corona PD pulse characteristics.","PeriodicalId":184139,"journal":{"name":"2018 IEEE Electrical Insulation Conference (EIC)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"19","resultStr":"{\"title\":\"Investigation of Corona Partial Discharge Characteristics Under Variable Frequency and Air Pressure\",\"authors\":\"A. Esfahani, S. Shahabi, G. Stone, B. Kordi\",\"doi\":\"10.1109/EIC.2018.8481047\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The rapid growth of electric apparatus in the more electric aircraft (MEA) causes the necessity to step up the electrical power. This, in turn, requires to a higher voltage which increases the electrical stress on insulation system. This can cause partial discharge (PD) in aircraft insulation system. Also, the aircraft generator provides electrical power with variable frequency. The insulation system of aircraft generator experiences different range of air pressure levels under variable voltage frequency. There is an interest on partial discharge detection under this condition. This paper presents the experimental tests that have been conducted to study the impact of voltage frequency and air pressure on corona PD pulse characteristics.\",\"PeriodicalId\":184139,\"journal\":{\"name\":\"2018 IEEE Electrical Insulation Conference (EIC)\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"19\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE Electrical Insulation Conference (EIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EIC.2018.8481047\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC.2018.8481047","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

摘要

电动飞机中电气设备的快速增长,导致了提高电力的必要性。这反过来又需要更高的电压,这增加了绝缘系统上的电应力。这可能导致飞机绝缘系统局部放电。此外,飞机发电机提供可变频率的电力。飞机发电机绝缘系统在变电压频率下经历不同的气压范围。在这种情况下,对局部放电检测有兴趣。本文介绍了电压频率和气压对电晕放电脉冲特性影响的实验研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation of Corona Partial Discharge Characteristics Under Variable Frequency and Air Pressure
The rapid growth of electric apparatus in the more electric aircraft (MEA) causes the necessity to step up the electrical power. This, in turn, requires to a higher voltage which increases the electrical stress on insulation system. This can cause partial discharge (PD) in aircraft insulation system. Also, the aircraft generator provides electrical power with variable frequency. The insulation system of aircraft generator experiences different range of air pressure levels under variable voltage frequency. There is an interest on partial discharge detection under this condition. This paper presents the experimental tests that have been conducted to study the impact of voltage frequency and air pressure on corona PD pulse characteristics.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信