{"title":"有功配电网故障区段定位方法研究","authors":"X. Wen, G. Zou, Chenghan Zhou, Liangzhi Sun, Xiaogong Du","doi":"10.1109/ACPEE51499.2021.9437099","DOIUrl":null,"url":null,"abstract":"The integration of distributed generators (DGs) changes the fault characteristics when a fault occurs in the feeder of distribution network, which makes the traditional faulty section location (FSL) method not applicable. In response to this problem, by analyzing the positive sequence fault component (PSFC) of current in distribution network with different types of DGs, a novel differential protection method is proposed in this paper. This method can adapt to the needs of FSL in different scenarios with high sensitivity. And it is not affected by the fault ride-through current. Finally, a simulation model is constructed in PSCAD/EMTDC to verify the validity of the proposed method.","PeriodicalId":127882,"journal":{"name":"2021 6th Asia Conference on Power and Electrical Engineering (ACPEE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research on Faulty Section Location Method for Active Distribution Network\",\"authors\":\"X. Wen, G. Zou, Chenghan Zhou, Liangzhi Sun, Xiaogong Du\",\"doi\":\"10.1109/ACPEE51499.2021.9437099\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The integration of distributed generators (DGs) changes the fault characteristics when a fault occurs in the feeder of distribution network, which makes the traditional faulty section location (FSL) method not applicable. In response to this problem, by analyzing the positive sequence fault component (PSFC) of current in distribution network with different types of DGs, a novel differential protection method is proposed in this paper. This method can adapt to the needs of FSL in different scenarios with high sensitivity. And it is not affected by the fault ride-through current. Finally, a simulation model is constructed in PSCAD/EMTDC to verify the validity of the proposed method.\",\"PeriodicalId\":127882,\"journal\":{\"name\":\"2021 6th Asia Conference on Power and Electrical Engineering (ACPEE)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 6th Asia Conference on Power and Electrical Engineering (ACPEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ACPEE51499.2021.9437099\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 6th Asia Conference on Power and Electrical Engineering (ACPEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ACPEE51499.2021.9437099","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

分布式发电机的集成改变了配电网馈线发生故障时的故障特征,使得传统的故障段定位方法不再适用。针对这一问题,本文通过对配电网中不同类型dg的电流正序故障分量(PSFC)的分析,提出了一种新的差动保护方法。该方法具有较高的灵敏度,能够适应不同场景下FSL的需求。并且不受故障穿通电流的影响。最后,在PSCAD/EMTDC中建立了仿真模型,验证了所提方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Research on Faulty Section Location Method for Active Distribution Network
The integration of distributed generators (DGs) changes the fault characteristics when a fault occurs in the feeder of distribution network, which makes the traditional faulty section location (FSL) method not applicable. In response to this problem, by analyzing the positive sequence fault component (PSFC) of current in distribution network with different types of DGs, a novel differential protection method is proposed in this paper. This method can adapt to the needs of FSL in different scenarios with high sensitivity. And it is not affected by the fault ride-through current. Finally, a simulation model is constructed in PSCAD/EMTDC to verify the validity of the proposed method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信