电缆模型中的非横向静电场

T. Nahring
{"title":"电缆模型中的非横向静电场","authors":"T. Nahring","doi":"10.1109/SPI.2004.1409033","DOIUrl":null,"url":null,"abstract":"Potentials of electrostatic fields in models of straight shielded cables are often assumed to be cylindrical (i.e., independent of the coordinate in axial direction of the cable). We give a rigorous motivation for this assumption. From the boundary conditions at the cable ends of shielded cables there result deviations of the potential from the cylindrical potential in the proximity of the cable ends. Such deviations were firstly introduced as residual potentials by us at ISTET '03. Here, we present new optimized estimations for residual potentials. To a nontrivial residual potential, there corresponds nontransversal electrostatic field strength, denoted as residual field strength. For the first time, we discuss an estimation of the residual field strength along the conductors of a cable model in this paper.","PeriodicalId":119776,"journal":{"name":"Proceedings. 8th IEEE Workshop on Signal Propagation on Interconnects","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2004-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Nontransversal electrostatic fields in cable models\",\"authors\":\"T. Nahring\",\"doi\":\"10.1109/SPI.2004.1409033\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Potentials of electrostatic fields in models of straight shielded cables are often assumed to be cylindrical (i.e., independent of the coordinate in axial direction of the cable). We give a rigorous motivation for this assumption. From the boundary conditions at the cable ends of shielded cables there result deviations of the potential from the cylindrical potential in the proximity of the cable ends. Such deviations were firstly introduced as residual potentials by us at ISTET '03. Here, we present new optimized estimations for residual potentials. To a nontrivial residual potential, there corresponds nontransversal electrostatic field strength, denoted as residual field strength. For the first time, we discuss an estimation of the residual field strength along the conductors of a cable model in this paper.\",\"PeriodicalId\":119776,\"journal\":{\"name\":\"Proceedings. 8th IEEE Workshop on Signal Propagation on Interconnects\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-05-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings. 8th IEEE Workshop on Signal Propagation on Interconnects\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SPI.2004.1409033\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. 8th IEEE Workshop on Signal Propagation on Interconnects","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPI.2004.1409033","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

直屏蔽电缆模型中的静电场电位通常假定为圆柱形(即与电缆轴向坐标无关)。我们给出了这个假设的严格动机。从屏蔽电缆电缆端面的边界条件出发,在电缆端面附近会产生电势与圆柱电势的偏差。这种偏差最初是由我们在2003年ISTET上作为剩余电位引入的。在这里,我们提出了新的优化残差电位估计。非平凡剩余电位对应非横向静电场强,记为剩余场强。本文首次讨论了沿电缆模型导体残余场强的估计问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Nontransversal electrostatic fields in cable models
Potentials of electrostatic fields in models of straight shielded cables are often assumed to be cylindrical (i.e., independent of the coordinate in axial direction of the cable). We give a rigorous motivation for this assumption. From the boundary conditions at the cable ends of shielded cables there result deviations of the potential from the cylindrical potential in the proximity of the cable ends. Such deviations were firstly introduced as residual potentials by us at ISTET '03. Here, we present new optimized estimations for residual potentials. To a nontrivial residual potential, there corresponds nontransversal electrostatic field strength, denoted as residual field strength. For the first time, we discuss an estimation of the residual field strength along the conductors of a cable model in this paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信