{"title":"暂态极限配电网中的密封蓄电池。内阻测量方法","authors":"I. Sajfar, M. Malarić, R. P. Bullough","doi":"10.1109/INTLEC.1990.171286","DOIUrl":null,"url":null,"abstract":"As the internal resistance (R/sub i/) of a battery directly influences the battery voltage drop, R/sub i/ is regarded as a key parameter in the design of high-ohmic distribution systems with transient limitation. Different methods of R/sub i/ measurement supply different results, especially those obtained in different states of discharge. For the project engineering of high-ohmic distribution systems with transient limitation the method of R/sub i/ measurement with short circuit current limitation is decisive. The measurement method is recommended which provides the best results for a high-ohmic distribution with transient limitation, and the results are confirmed by measurements performed in the power supply circuit interrupted by a fuse. The dependence of internal resistance on the state of charge of the battery obtained by various methods is discussed.<<ETX>>","PeriodicalId":264940,"journal":{"name":"12th International Conference on Telecommunications Energy","volume":"53 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1990-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Sealed batteries in transient limiting distribution networks-methods of measuring their internal resistance\",\"authors\":\"I. Sajfar, M. Malarić, R. P. Bullough\",\"doi\":\"10.1109/INTLEC.1990.171286\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As the internal resistance (R/sub i/) of a battery directly influences the battery voltage drop, R/sub i/ is regarded as a key parameter in the design of high-ohmic distribution systems with transient limitation. Different methods of R/sub i/ measurement supply different results, especially those obtained in different states of discharge. For the project engineering of high-ohmic distribution systems with transient limitation the method of R/sub i/ measurement with short circuit current limitation is decisive. The measurement method is recommended which provides the best results for a high-ohmic distribution with transient limitation, and the results are confirmed by measurements performed in the power supply circuit interrupted by a fuse. The dependence of internal resistance on the state of charge of the battery obtained by various methods is discussed.<<ETX>>\",\"PeriodicalId\":264940,\"journal\":{\"name\":\"12th International Conference on Telecommunications Energy\",\"volume\":\"53 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"12th International Conference on Telecommunications Energy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INTLEC.1990.171286\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"12th International Conference on Telecommunications Energy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTLEC.1990.171286","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Sealed batteries in transient limiting distribution networks-methods of measuring their internal resistance
As the internal resistance (R/sub i/) of a battery directly influences the battery voltage drop, R/sub i/ is regarded as a key parameter in the design of high-ohmic distribution systems with transient limitation. Different methods of R/sub i/ measurement supply different results, especially those obtained in different states of discharge. For the project engineering of high-ohmic distribution systems with transient limitation the method of R/sub i/ measurement with short circuit current limitation is decisive. The measurement method is recommended which provides the best results for a high-ohmic distribution with transient limitation, and the results are confirmed by measurements performed in the power supply circuit interrupted by a fuse. The dependence of internal resistance on the state of charge of the battery obtained by various methods is discussed.<>