一种用于检测糖尿病患者低血糖事件的可穿戴、低成本手部震颤传感器

H. Abbas, Karim Zahed, L. Alic, Yibo Zhu, F. Sasangohar, Ranjana K. Mehta, M. Lawley, Q. Abbasi, K. Qaraqe
{"title":"一种用于检测糖尿病患者低血糖事件的可穿戴、低成本手部震颤传感器","authors":"H. Abbas, Karim Zahed, L. Alic, Yibo Zhu, F. Sasangohar, Ranjana K. Mehta, M. Lawley, Q. Abbasi, K. Qaraqe","doi":"10.1109/RFM.2018.8846546","DOIUrl":null,"url":null,"abstract":"Severe hypoglycemia leverages complication in diabetes patients: e.g., it increases death rate by a six-fold. Therefore, early detection and prediction of hypoglycemic events are of utmost importance. This publication presents a prototype of a wearable hand-tremor system that detects the onset of hypoglycemic events. The results show the prototype is capable of simulating anticipated frequency and amplitude of the tremor relevant for hypoglycemic events. The initial functional performance-tests demonstrate a maximum error of 4.75% in the detecting the tremor frequency.","PeriodicalId":111726,"journal":{"name":"2018 IEEE International RF and Microwave Conference (RFM)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"A Wearable, Low-cost Hand Tremor Sensor for Detecting Hypoglycemic Events in Diabetic Patients\",\"authors\":\"H. Abbas, Karim Zahed, L. Alic, Yibo Zhu, F. Sasangohar, Ranjana K. Mehta, M. Lawley, Q. Abbasi, K. Qaraqe\",\"doi\":\"10.1109/RFM.2018.8846546\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Severe hypoglycemia leverages complication in diabetes patients: e.g., it increases death rate by a six-fold. Therefore, early detection and prediction of hypoglycemic events are of utmost importance. This publication presents a prototype of a wearable hand-tremor system that detects the onset of hypoglycemic events. The results show the prototype is capable of simulating anticipated frequency and amplitude of the tremor relevant for hypoglycemic events. The initial functional performance-tests demonstrate a maximum error of 4.75% in the detecting the tremor frequency.\",\"PeriodicalId\":111726,\"journal\":{\"name\":\"2018 IEEE International RF and Microwave Conference (RFM)\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE International RF and Microwave Conference (RFM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RFM.2018.8846546\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE International RF and Microwave Conference (RFM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RFM.2018.8846546","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

严重低血糖会影响糖尿病患者的并发症:例如,它会使死亡率增加六倍。因此,早期发现和预测低血糖事件是至关重要的。本出版物介绍了一种可穿戴的手部震颤系统的原型,该系统可以检测低血糖事件的发生。结果表明,该原型能够模拟与低血糖事件相关的震颤的预期频率和幅度。初步的功能性能测试表明,该方法检测震颤频率的最大误差为4.75%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Wearable, Low-cost Hand Tremor Sensor for Detecting Hypoglycemic Events in Diabetic Patients
Severe hypoglycemia leverages complication in diabetes patients: e.g., it increases death rate by a six-fold. Therefore, early detection and prediction of hypoglycemic events are of utmost importance. This publication presents a prototype of a wearable hand-tremor system that detects the onset of hypoglycemic events. The results show the prototype is capable of simulating anticipated frequency and amplitude of the tremor relevant for hypoglycemic events. The initial functional performance-tests demonstrate a maximum error of 4.75% in the detecting the tremor frequency.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信