Ivan Ottinger, T. Ludwig, E. Miklovičová, V. Batora, J. Murgas, Marian Tarnik
{"title":"用于验证自适应控制器的个性化T1DM模拟器","authors":"Ivan Ottinger, T. Ludwig, E. Miklovičová, V. Batora, J. Murgas, Marian Tarnik","doi":"10.1109/PC.2015.7169986","DOIUrl":null,"url":null,"abstract":"Individualized type 1 diabetes mellitus (T1DM) subject model is presented in this paper. Insulin-glucose subsystem based on Bergman's minimal model is coupled with subcutaneous insulin absorption and absorption of digested carbohydrates. Identification of model parameters was performed on pharmacokinetics and pharmacodynamics characteristics of administered insulin and data collected from continuous glucose monitoring (CGM) system. The identified model served as a basis for designing a model reference adaptive controller.","PeriodicalId":173529,"journal":{"name":"2015 20th International Conference on Process Control (PC)","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Individualized T1DM simulator for verification of adaptive controller\",\"authors\":\"Ivan Ottinger, T. Ludwig, E. Miklovičová, V. Batora, J. Murgas, Marian Tarnik\",\"doi\":\"10.1109/PC.2015.7169986\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Individualized type 1 diabetes mellitus (T1DM) subject model is presented in this paper. Insulin-glucose subsystem based on Bergman's minimal model is coupled with subcutaneous insulin absorption and absorption of digested carbohydrates. Identification of model parameters was performed on pharmacokinetics and pharmacodynamics characteristics of administered insulin and data collected from continuous glucose monitoring (CGM) system. The identified model served as a basis for designing a model reference adaptive controller.\",\"PeriodicalId\":173529,\"journal\":{\"name\":\"2015 20th International Conference on Process Control (PC)\",\"volume\":\"57 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 20th International Conference on Process Control (PC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PC.2015.7169986\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 20th International Conference on Process Control (PC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PC.2015.7169986","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Individualized T1DM simulator for verification of adaptive controller
Individualized type 1 diabetes mellitus (T1DM) subject model is presented in this paper. Insulin-glucose subsystem based on Bergman's minimal model is coupled with subcutaneous insulin absorption and absorption of digested carbohydrates. Identification of model parameters was performed on pharmacokinetics and pharmacodynamics characteristics of administered insulin and data collected from continuous glucose monitoring (CGM) system. The identified model served as a basis for designing a model reference adaptive controller.