3左室收缩功能监测

Priv.-Doz. Dr. Med. Axel Goertz (Leitender Klinischer Oberarzt)
{"title":"3左室收缩功能监测","authors":"Priv.-Doz. Dr. Med. Axel Goertz (Leitender Klinischer Oberarzt)","doi":"10.1016/S0950-3501(98)80016-0","DOIUrl":null,"url":null,"abstract":"<div><p>Transoesophageal echocardiography has gained the role of a standard monitoring technique for both cardiac surgical patients and patients with increased cardiac risk under-going non-cardiac surgery. It offers unique information about left ventricular global and regional performance on a ‘beat-to-beat’ basis without subjecting the patient to a major degree of invasiveness. In addition to the fact that considerable experience is required to obtain reliably (and to maintain) the standard monitoring view of the left ventricle and to identify correctly the cardiac structures of interest, there are some other limitations inherent to the method that have to be recognized in order to obtain reliable results. In particular, the fact that with recent technological advances, such as acoustic quantification, on-line display of various left ventricular function parameters is provided which could blind us to possible sources of error. This and future technological developments should be used to their full potential but any pseudoaccuracy must not be overlooked.</p></div>","PeriodicalId":80610,"journal":{"name":"Bailliere's clinical anaesthesiology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1998-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0950-3501(98)80016-0","citationCount":"0","resultStr":"{\"title\":\"3 Monitoring of left ventricular systolic function\",\"authors\":\"Priv.-Doz. Dr. Med. Axel Goertz (Leitender Klinischer Oberarzt)\",\"doi\":\"10.1016/S0950-3501(98)80016-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Transoesophageal echocardiography has gained the role of a standard monitoring technique for both cardiac surgical patients and patients with increased cardiac risk under-going non-cardiac surgery. It offers unique information about left ventricular global and regional performance on a ‘beat-to-beat’ basis without subjecting the patient to a major degree of invasiveness. In addition to the fact that considerable experience is required to obtain reliably (and to maintain) the standard monitoring view of the left ventricle and to identify correctly the cardiac structures of interest, there are some other limitations inherent to the method that have to be recognized in order to obtain reliable results. In particular, the fact that with recent technological advances, such as acoustic quantification, on-line display of various left ventricular function parameters is provided which could blind us to possible sources of error. This and future technological developments should be used to their full potential but any pseudoaccuracy must not be overlooked.</p></div>\",\"PeriodicalId\":80610,\"journal\":{\"name\":\"Bailliere's clinical anaesthesiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/S0950-3501(98)80016-0\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bailliere's clinical anaesthesiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0950350198800160\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bailliere's clinical anaesthesiology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0950350198800160","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

经食管超声心动图已成为心脏手术患者和接受非心脏手术的心脏风险增加的患者的标准监测技术。它提供了独特的信息,关于左心室整体和区域的表现,在“搏动”的基础上,而不会使患者受到很大程度的侵入。除了需要大量的经验来获得(并维持)左心室的标准监测视图并正确识别感兴趣的心脏结构之外,为了获得可靠的结果,必须认识到该方法固有的一些其他限制。特别是,随着声学量化等最新技术的进步,各种左心室功能参数的在线显示可能会使我们看不到可能的误差来源。这和未来的技术发展应该充分发挥其潜力,但任何伪准确性都不能忽视。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
3 Monitoring of left ventricular systolic function

Transoesophageal echocardiography has gained the role of a standard monitoring technique for both cardiac surgical patients and patients with increased cardiac risk under-going non-cardiac surgery. It offers unique information about left ventricular global and regional performance on a ‘beat-to-beat’ basis without subjecting the patient to a major degree of invasiveness. In addition to the fact that considerable experience is required to obtain reliably (and to maintain) the standard monitoring view of the left ventricle and to identify correctly the cardiac structures of interest, there are some other limitations inherent to the method that have to be recognized in order to obtain reliable results. In particular, the fact that with recent technological advances, such as acoustic quantification, on-line display of various left ventricular function parameters is provided which could blind us to possible sources of error. This and future technological developments should be used to their full potential but any pseudoaccuracy must not be overlooked.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信