恒负载DC-DC变换器的有限集预测鲁棒控制

Hoda Sorouri, M. Sedighizadeh
{"title":"恒负载DC-DC变换器的有限集预测鲁棒控制","authors":"Hoda Sorouri, M. Sedighizadeh","doi":"10.1109/pedstc53976.2022.9767487","DOIUrl":null,"url":null,"abstract":"Today, power distribution systems are highly penetrated by renewable energy sources, and this explains the dominant role of power electronic converters in their operation. However, the existence of several electronic power conversion units creates the so-called constant power load (CPL), which poses a serious stability issue in the operation of a DC microgrid. So, a robust controller with fast response is vital. This paper develops a small signal model for dc MGs from the control point of view, in order to study stability analysis and investigate effects of CPLs. A finite-set model predictive control (FS-MPC) is used to control of dc-dc buck converter in uncertain situations, i.e. when reference voltage changes and when input voltage of converter was changed. To evaluate the strangeness of the proposed controller comparative real time results and analysis of MPC with Backstepping and PID control is observed.","PeriodicalId":213924,"journal":{"name":"2022 13th Power Electronics, Drive Systems, and Technologies Conference (PEDSTC)","volume":"75 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Robust control of DC-DC converter supplying constant power load with Finite-Set Model Predictive Control\",\"authors\":\"Hoda Sorouri, M. Sedighizadeh\",\"doi\":\"10.1109/pedstc53976.2022.9767487\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Today, power distribution systems are highly penetrated by renewable energy sources, and this explains the dominant role of power electronic converters in their operation. However, the existence of several electronic power conversion units creates the so-called constant power load (CPL), which poses a serious stability issue in the operation of a DC microgrid. So, a robust controller with fast response is vital. This paper develops a small signal model for dc MGs from the control point of view, in order to study stability analysis and investigate effects of CPLs. A finite-set model predictive control (FS-MPC) is used to control of dc-dc buck converter in uncertain situations, i.e. when reference voltage changes and when input voltage of converter was changed. To evaluate the strangeness of the proposed controller comparative real time results and analysis of MPC with Backstepping and PID control is observed.\",\"PeriodicalId\":213924,\"journal\":{\"name\":\"2022 13th Power Electronics, Drive Systems, and Technologies Conference (PEDSTC)\",\"volume\":\"75 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 13th Power Electronics, Drive Systems, and Technologies Conference (PEDSTC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/pedstc53976.2022.9767487\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 13th Power Electronics, Drive Systems, and Technologies Conference (PEDSTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/pedstc53976.2022.9767487","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

今天,可再生能源已高度渗透到配电系统中,这就解释了电力电子变流器在其运行中的主导作用。然而,多个电子功率转换单元的存在产生了所谓的恒功率负载(CPL),这给直流微电网的运行带来了严重的稳定性问题。因此,具有快速响应的鲁棒控制器至关重要。本文从控制的角度出发,建立了直流电机的小信号模型,以研究其稳定性分析和对CPLs的影响。有限集模型预测控制(FS-MPC)用于不确定情况下,即参考电压变化和变换器输入电压变化时的dc-dc降压变换器控制。为了评价所提出的控制器的奇异性,比较了MPC反步控制和PID控制的实时结果和分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Robust control of DC-DC converter supplying constant power load with Finite-Set Model Predictive Control
Today, power distribution systems are highly penetrated by renewable energy sources, and this explains the dominant role of power electronic converters in their operation. However, the existence of several electronic power conversion units creates the so-called constant power load (CPL), which poses a serious stability issue in the operation of a DC microgrid. So, a robust controller with fast response is vital. This paper develops a small signal model for dc MGs from the control point of view, in order to study stability analysis and investigate effects of CPLs. A finite-set model predictive control (FS-MPC) is used to control of dc-dc buck converter in uncertain situations, i.e. when reference voltage changes and when input voltage of converter was changed. To evaluate the strangeness of the proposed controller comparative real time results and analysis of MPC with Backstepping and PID control is observed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信