{"title":"电力系统Xlpe电缆局部放电的测量","authors":"S. Singh, R. Rahore, Tarun Naruka","doi":"10.47904/ijskit.10.1.2020.36-41","DOIUrl":null,"url":null,"abstract":"Partial Discharge (PD) measurement is a new approach to find out insulation condition in power cables.Partial discharge (PD) inception test using conventional techniques covered in IEC 60270 and perform on the newly produced Cross linked poly ethylene XLPE cable. This test carried in PD lab Faraday cage where outer noise and electromagnetic fields not disturbed for testing fundamental condition. In PD testing main resonance reactor or HV transformer (LVDT) required for applying high voltage on cable, coupling capacitor, blocking capacitor with inductor for filtering harmonics.","PeriodicalId":424149,"journal":{"name":"SKIT Research Journal","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement of Partial Discharge In Xlpe Cables of Electrical Power System\",\"authors\":\"S. Singh, R. Rahore, Tarun Naruka\",\"doi\":\"10.47904/ijskit.10.1.2020.36-41\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Partial Discharge (PD) measurement is a new approach to find out insulation condition in power cables.Partial discharge (PD) inception test using conventional techniques covered in IEC 60270 and perform on the newly produced Cross linked poly ethylene XLPE cable. This test carried in PD lab Faraday cage where outer noise and electromagnetic fields not disturbed for testing fundamental condition. In PD testing main resonance reactor or HV transformer (LVDT) required for applying high voltage on cable, coupling capacitor, blocking capacitor with inductor for filtering harmonics.\",\"PeriodicalId\":424149,\"journal\":{\"name\":\"SKIT Research Journal\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-03-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SKIT Research Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47904/ijskit.10.1.2020.36-41\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SKIT Research Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47904/ijskit.10.1.2020.36-41","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Measurement of Partial Discharge In Xlpe Cables of Electrical Power System
Partial Discharge (PD) measurement is a new approach to find out insulation condition in power cables.Partial discharge (PD) inception test using conventional techniques covered in IEC 60270 and perform on the newly produced Cross linked poly ethylene XLPE cable. This test carried in PD lab Faraday cage where outer noise and electromagnetic fields not disturbed for testing fundamental condition. In PD testing main resonance reactor or HV transformer (LVDT) required for applying high voltage on cable, coupling capacitor, blocking capacitor with inductor for filtering harmonics.