燃气泄漏智能自动检测报警系统的研制

Sayeda Islam Nahid, Navid Anjum, N. Chowdhury, Laila Tamanna Anni, M. Mahmud, Mohammad Monirujjaman Khan, R. H. Ashique
{"title":"燃气泄漏智能自动检测报警系统的研制","authors":"Sayeda Islam Nahid, Navid Anjum, N. Chowdhury, Laila Tamanna Anni, M. Mahmud, Mohammad Monirujjaman Khan, R. H. Ashique","doi":"10.1109/iemcon53756.2021.9623207","DOIUrl":null,"url":null,"abstract":"In comparison to firewood and charcoal, LPG is widely used as a source of fuel, mainly in urban regions. Due to the extremely combustible nature of the gas, there is always the risk of gas leakage as a consequence of carelessness or failure of the regulating valve on the gas cylinder, which poses a significant risk. Gas-related fires are on the rise, which may be prevented by utilizing a gas leakage detection system, necessitating the creation of a microcontroller-based cooking gas detector. The use of a microcontroller allows for the creation of a highly precise and quick reaction time detecting system. The detector includes a MQ-6 LPG gas sensor, a PIC16F690 microcontroller, an LCD, a buzzer, and a number of LEDs to learn about the gas leak's condition. When a voltage signal is present from the MQ-6 sensor exceeds a specific threshold, the microcontroller detects the presence of a gas and sends an audiovisual alert. All peripherals are linked to the microcontroller through its pins, which are coded in the PIC assembly language. When the system was turned on, the microcontroller turned on a green LED to indicate that there was no gas leakage. A digital multimeter is used to monitor the sensor voltage signal when LPG gas is discharged. Whenever the voltage is less than 2.0V, the green light remains illuminated; when the voltage is more than 2.0V, the microcontroller blinks a red LED and sounds an alarm to indicate the presence of a gas. The alert can be recognized by pressing a button on the sensor. When the system was turned on, the microcontroller turned on a green LED to indicate that there was no gas leakage. A digital multimeter is used to monitor the sensor voltage signal when LPG gas is discharged. Whenever the voltage is less than 2.0V, the green light remains illuminated; when the voltage is more than 2.0V, the microcontroller blinks a red LED and sounds an alarm to indicate the presence of a gas. The alert can be recognized by pressing a button on the sensor.","PeriodicalId":272590,"journal":{"name":"2021 IEEE 12th Annual Information Technology, Electronics and Mobile Communication Conference (IEMCON)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Development of a Smart Automatic Gas Leakage Detector and Alarming System\",\"authors\":\"Sayeda Islam Nahid, Navid Anjum, N. Chowdhury, Laila Tamanna Anni, M. Mahmud, Mohammad Monirujjaman Khan, R. H. Ashique\",\"doi\":\"10.1109/iemcon53756.2021.9623207\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In comparison to firewood and charcoal, LPG is widely used as a source of fuel, mainly in urban regions. Due to the extremely combustible nature of the gas, there is always the risk of gas leakage as a consequence of carelessness or failure of the regulating valve on the gas cylinder, which poses a significant risk. Gas-related fires are on the rise, which may be prevented by utilizing a gas leakage detection system, necessitating the creation of a microcontroller-based cooking gas detector. The use of a microcontroller allows for the creation of a highly precise and quick reaction time detecting system. The detector includes a MQ-6 LPG gas sensor, a PIC16F690 microcontroller, an LCD, a buzzer, and a number of LEDs to learn about the gas leak's condition. When a voltage signal is present from the MQ-6 sensor exceeds a specific threshold, the microcontroller detects the presence of a gas and sends an audiovisual alert. All peripherals are linked to the microcontroller through its pins, which are coded in the PIC assembly language. When the system was turned on, the microcontroller turned on a green LED to indicate that there was no gas leakage. A digital multimeter is used to monitor the sensor voltage signal when LPG gas is discharged. Whenever the voltage is less than 2.0V, the green light remains illuminated; when the voltage is more than 2.0V, the microcontroller blinks a red LED and sounds an alarm to indicate the presence of a gas. The alert can be recognized by pressing a button on the sensor. When the system was turned on, the microcontroller turned on a green LED to indicate that there was no gas leakage. A digital multimeter is used to monitor the sensor voltage signal when LPG gas is discharged. Whenever the voltage is less than 2.0V, the green light remains illuminated; when the voltage is more than 2.0V, the microcontroller blinks a red LED and sounds an alarm to indicate the presence of a gas. The alert can be recognized by pressing a button on the sensor.\",\"PeriodicalId\":272590,\"journal\":{\"name\":\"2021 IEEE 12th Annual Information Technology, Electronics and Mobile Communication Conference (IEMCON)\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE 12th Annual Information Technology, Electronics and Mobile Communication Conference (IEMCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/iemcon53756.2021.9623207\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 12th Annual Information Technology, Electronics and Mobile Communication Conference (IEMCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/iemcon53756.2021.9623207","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

与木柴和木炭相比,液化石油气被广泛用作燃料来源,主要是在城市地区。由于气体的极端可燃性,由于气瓶上的调节阀不小心或故障,总是存在气体泄漏的风险,这构成了重大风险。燃气相关的火灾正在上升,可以通过使用燃气泄漏检测系统来防止,这就需要创建一个基于微控制器的烹饪燃气探测器。微控制器的使用允许创建一个高度精确和快速反应时间检测系统。该探测器包括一个MQ-6 LPG气体传感器、一个PIC16F690微控制器、一个LCD、一个蜂鸣器和一些led,用于了解气体泄漏情况。当来自MQ-6传感器的电压信号超过特定阈值时,微控制器检测到气体的存在并发送视听警报。所有外设都通过引脚连接到微控制器,这些引脚用PIC汇编语言编码。当系统开机时,微控制器亮绿色LED,表示没有气体泄漏。数字万用表用于监测液化气放电时传感器的电压信号。当电压低于2.0V时,绿灯常亮;当电压大于2.0V时,微控制器闪烁红色LED并发出警报,指示存在气体。警报可以通过按下传感器上的按钮来识别。当系统开机时,微控制器亮绿色LED,表示没有气体泄漏。数字万用表用于监测液化气放电时传感器的电压信号。当电压低于2.0V时,绿灯常亮;当电压大于2.0V时,微控制器闪烁红色LED并发出警报,指示存在气体。警报可以通过按下传感器上的按钮来识别。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of a Smart Automatic Gas Leakage Detector and Alarming System
In comparison to firewood and charcoal, LPG is widely used as a source of fuel, mainly in urban regions. Due to the extremely combustible nature of the gas, there is always the risk of gas leakage as a consequence of carelessness or failure of the regulating valve on the gas cylinder, which poses a significant risk. Gas-related fires are on the rise, which may be prevented by utilizing a gas leakage detection system, necessitating the creation of a microcontroller-based cooking gas detector. The use of a microcontroller allows for the creation of a highly precise and quick reaction time detecting system. The detector includes a MQ-6 LPG gas sensor, a PIC16F690 microcontroller, an LCD, a buzzer, and a number of LEDs to learn about the gas leak's condition. When a voltage signal is present from the MQ-6 sensor exceeds a specific threshold, the microcontroller detects the presence of a gas and sends an audiovisual alert. All peripherals are linked to the microcontroller through its pins, which are coded in the PIC assembly language. When the system was turned on, the microcontroller turned on a green LED to indicate that there was no gas leakage. A digital multimeter is used to monitor the sensor voltage signal when LPG gas is discharged. Whenever the voltage is less than 2.0V, the green light remains illuminated; when the voltage is more than 2.0V, the microcontroller blinks a red LED and sounds an alarm to indicate the presence of a gas. The alert can be recognized by pressing a button on the sensor. When the system was turned on, the microcontroller turned on a green LED to indicate that there was no gas leakage. A digital multimeter is used to monitor the sensor voltage signal when LPG gas is discharged. Whenever the voltage is less than 2.0V, the green light remains illuminated; when the voltage is more than 2.0V, the microcontroller blinks a red LED and sounds an alarm to indicate the presence of a gas. The alert can be recognized by pressing a button on the sensor.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信