利用Matlab/Simulink对逆时过流继电器进行建模与仿真

N. Hussin, M. H. Idris, M. Amirruddin, M. S. Ahmad, M. A. Ismail, F. Abdullah, Nurhakimah Mohd Mukhta
{"title":"利用Matlab/Simulink对逆时过流继电器进行建模与仿真","authors":"N. Hussin, M. H. Idris, M. Amirruddin, M. S. Ahmad, M. A. Ismail, F. Abdullah, Nurhakimah Mohd Mukhta","doi":"10.1109/I2CACIS.2016.7885286","DOIUrl":null,"url":null,"abstract":"Overcurrent relay is an important relay used to protect transmission and distribution feeders, transformer, bus coupler etc. It can be used as main or backup protection relays. The modeling of overcurrent relay and other protection relays is important in the research on the effects of network parameters and configurations on the operation of these relays. This research deal with modeling and simulation of inverse time overcurrent relay using commonly used Matlab/Simulink software. The developed model was tested with single line to ground fault and phase to phase fault with various fault locations and fault resistances to evaluate phase and earth detectors in sensing the fault current. Simulations results show the feasibility of the software to be used to develop the relay.","PeriodicalId":399080,"journal":{"name":"2016 IEEE International Conference on Automatic Control and Intelligent Systems (I2CACIS)","volume":"60 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"Modeling and simulation of inverse time overcurrent relay using Matlab/Simulink\",\"authors\":\"N. Hussin, M. H. Idris, M. Amirruddin, M. S. Ahmad, M. A. Ismail, F. Abdullah, Nurhakimah Mohd Mukhta\",\"doi\":\"10.1109/I2CACIS.2016.7885286\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Overcurrent relay is an important relay used to protect transmission and distribution feeders, transformer, bus coupler etc. It can be used as main or backup protection relays. The modeling of overcurrent relay and other protection relays is important in the research on the effects of network parameters and configurations on the operation of these relays. This research deal with modeling and simulation of inverse time overcurrent relay using commonly used Matlab/Simulink software. The developed model was tested with single line to ground fault and phase to phase fault with various fault locations and fault resistances to evaluate phase and earth detectors in sensing the fault current. Simulations results show the feasibility of the software to be used to develop the relay.\",\"PeriodicalId\":399080,\"journal\":{\"name\":\"2016 IEEE International Conference on Automatic Control and Intelligent Systems (I2CACIS)\",\"volume\":\"60 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE International Conference on Automatic Control and Intelligent Systems (I2CACIS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/I2CACIS.2016.7885286\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Conference on Automatic Control and Intelligent Systems (I2CACIS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/I2CACIS.2016.7885286","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

摘要

过流继电器是一种重要的继电器,用于保护输配电馈线、变压器、母线耦合器等。它可以用作主或备用保护继电器。在研究过流继电器和其他保护继电器的网络参数和配置对其运行的影响时,对过流继电器和其他保护继电器进行建模是非常重要的。本课题利用常用的Matlab/Simulink软件对逆时过流继电器进行建模与仿真。采用不同故障位置和故障电阻的单线对地故障和相对相故障对模型进行了测试,以评估相检波器和接地检波器对故障电流的感知能力。仿真结果表明了该软件用于继电器研制的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Modeling and simulation of inverse time overcurrent relay using Matlab/Simulink
Overcurrent relay is an important relay used to protect transmission and distribution feeders, transformer, bus coupler etc. It can be used as main or backup protection relays. The modeling of overcurrent relay and other protection relays is important in the research on the effects of network parameters and configurations on the operation of these relays. This research deal with modeling and simulation of inverse time overcurrent relay using commonly used Matlab/Simulink software. The developed model was tested with single line to ground fault and phase to phase fault with various fault locations and fault resistances to evaluate phase and earth detectors in sensing the fault current. Simulations results show the feasibility of the software to be used to develop the relay.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信