人体皮肤诊断用毫米波探头的设计

N. Janssen, P. Smulders
{"title":"人体皮肤诊断用毫米波探头的设计","authors":"N. Janssen, P. Smulders","doi":"10.23919/EUMC.2012.6459262","DOIUrl":null,"url":null,"abstract":"Millimeter-wave reflectometry is a potentially interesting method to measure varying properties of human-skin tissue. With this method, an open-ended waveguide probe is used, which is pressed against the skin (or bandage), to measure the reflection coefficient in the millimeter-wave frequency band of 40-60 GHz. Thanks to todays low-cost millimeter-wave silicon-based chip technology, this method could possibly be made available for massive usage in home-care situations. However, the measurement conditions in such situations might be ill-defined in the sense that parameters such as probe pressure and probeskin angle are not well controlled. In this paper, two candidate probe types are investigated as regards the sensitivity for probe pressure on the skin, probe-skin angle and layers of bandage between probe and skin. The probes considered are either with or without flange. The unflanged probe turns out to be the most promising candidate provided that careful calibration is possible despite the missing flange.","PeriodicalId":266910,"journal":{"name":"2012 42nd European Microwave Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Design of millimeter-wave probe for diagnosis of human skin\",\"authors\":\"N. Janssen, P. Smulders\",\"doi\":\"10.23919/EUMC.2012.6459262\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Millimeter-wave reflectometry is a potentially interesting method to measure varying properties of human-skin tissue. With this method, an open-ended waveguide probe is used, which is pressed against the skin (or bandage), to measure the reflection coefficient in the millimeter-wave frequency band of 40-60 GHz. Thanks to todays low-cost millimeter-wave silicon-based chip technology, this method could possibly be made available for massive usage in home-care situations. However, the measurement conditions in such situations might be ill-defined in the sense that parameters such as probe pressure and probeskin angle are not well controlled. In this paper, two candidate probe types are investigated as regards the sensitivity for probe pressure on the skin, probe-skin angle and layers of bandage between probe and skin. The probes considered are either with or without flange. The unflanged probe turns out to be the most promising candidate provided that careful calibration is possible despite the missing flange.\",\"PeriodicalId\":266910,\"journal\":{\"name\":\"2012 42nd European Microwave Conference\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 42nd European Microwave Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/EUMC.2012.6459262\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 42nd European Microwave Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/EUMC.2012.6459262","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

毫米波反射法是一种潜在的有趣的方法来测量人体皮肤组织的不同特性。该方法使用一个开放式波导探头,将其压在皮肤(或绷带)上,测量40-60 GHz毫米波频段的反射系数。由于今天低成本的毫米波硅基芯片技术,这种方法可能在家庭护理情况下大量使用。然而,在这种情况下的测量条件可能是不明确的,因为诸如探头压力和探头皮角等参数没有得到很好的控制。本文研究了两种候选探头类型对探头压力对皮肤的敏感性、探头与皮肤之间的角度以及探头与皮肤之间的绷带层数。所考虑的探头要么带法兰,要么不带法兰。无法兰的探头被证明是最有希望的候选者,只要仔细校准是可能的,尽管缺少法兰。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of millimeter-wave probe for diagnosis of human skin
Millimeter-wave reflectometry is a potentially interesting method to measure varying properties of human-skin tissue. With this method, an open-ended waveguide probe is used, which is pressed against the skin (or bandage), to measure the reflection coefficient in the millimeter-wave frequency band of 40-60 GHz. Thanks to todays low-cost millimeter-wave silicon-based chip technology, this method could possibly be made available for massive usage in home-care situations. However, the measurement conditions in such situations might be ill-defined in the sense that parameters such as probe pressure and probeskin angle are not well controlled. In this paper, two candidate probe types are investigated as regards the sensitivity for probe pressure on the skin, probe-skin angle and layers of bandage between probe and skin. The probes considered are either with or without flange. The unflanged probe turns out to be the most promising candidate provided that careful calibration is possible despite the missing flange.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信