Hendri Masdi, Norman Mariun, S. Mahmud, Azah Mohamed, S. Yusuf
{"title":"用于电压暂降缓解的D-STATCOM原型设计","authors":"Hendri Masdi, Norman Mariun, S. Mahmud, Azah Mohamed, S. Yusuf","doi":"10.1109/PECON.2004.1461617","DOIUrl":null,"url":null,"abstract":"This paper presents the design of a prototype distribution static compensator (D-STATCOM) for voltage sag mitigation in an unbalanced distribution system. The D-STATCOM is intended to replace the widely used static Var compensator (SVC). For fast response requirement, the feedforward compensation scheme is employed to enable the D-STATCOM to mitigate voltage sag and at the same time correct the power factor, thus acting as a load compensator. The compensation scheme of the D-STATCOM is derived using the symmetrical component method. In this work, the 12-pulse D-STATCOM configuration with IGBT has been designed and the graphic based models of the D-STATCOM have been developed using the PSCAD/EMTDC electromagnetic transient simulation program. Accordingly, simulations are first carried out to illustrate the use of D-STATCOM in mitigating voltage sag in a distribution system. Simulation results prove that the D-STATCOM is capable of mitigating voltage sag as well as improving power quality of a system.","PeriodicalId":375856,"journal":{"name":"PECon 2004. Proceedings. National Power and Energy Conference, 2004.","volume":"67 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"78","resultStr":"{\"title\":\"Design of a prototype D-STATCOM for voltage sag mitigation\",\"authors\":\"Hendri Masdi, Norman Mariun, S. Mahmud, Azah Mohamed, S. Yusuf\",\"doi\":\"10.1109/PECON.2004.1461617\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the design of a prototype distribution static compensator (D-STATCOM) for voltage sag mitigation in an unbalanced distribution system. The D-STATCOM is intended to replace the widely used static Var compensator (SVC). For fast response requirement, the feedforward compensation scheme is employed to enable the D-STATCOM to mitigate voltage sag and at the same time correct the power factor, thus acting as a load compensator. The compensation scheme of the D-STATCOM is derived using the symmetrical component method. In this work, the 12-pulse D-STATCOM configuration with IGBT has been designed and the graphic based models of the D-STATCOM have been developed using the PSCAD/EMTDC electromagnetic transient simulation program. Accordingly, simulations are first carried out to illustrate the use of D-STATCOM in mitigating voltage sag in a distribution system. Simulation results prove that the D-STATCOM is capable of mitigating voltage sag as well as improving power quality of a system.\",\"PeriodicalId\":375856,\"journal\":{\"name\":\"PECon 2004. Proceedings. National Power and Energy Conference, 2004.\",\"volume\":\"67 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-11-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"78\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PECon 2004. Proceedings. National Power and Energy Conference, 2004.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PECON.2004.1461617\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PECon 2004. Proceedings. National Power and Energy Conference, 2004.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECON.2004.1461617","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design of a prototype D-STATCOM for voltage sag mitigation
This paper presents the design of a prototype distribution static compensator (D-STATCOM) for voltage sag mitigation in an unbalanced distribution system. The D-STATCOM is intended to replace the widely used static Var compensator (SVC). For fast response requirement, the feedforward compensation scheme is employed to enable the D-STATCOM to mitigate voltage sag and at the same time correct the power factor, thus acting as a load compensator. The compensation scheme of the D-STATCOM is derived using the symmetrical component method. In this work, the 12-pulse D-STATCOM configuration with IGBT has been designed and the graphic based models of the D-STATCOM have been developed using the PSCAD/EMTDC electromagnetic transient simulation program. Accordingly, simulations are first carried out to illustrate the use of D-STATCOM in mitigating voltage sag in a distribution system. Simulation results prove that the D-STATCOM is capable of mitigating voltage sag as well as improving power quality of a system.