基于偏振动态显示的难以察觉标记注视估计

Yutaro Inoue, Koki Koshikawa, K. Takemura
{"title":"基于偏振动态显示的难以察觉标记注视估计","authors":"Yutaro Inoue, Koki Koshikawa, K. Takemura","doi":"10.1145/3517031.3529640","DOIUrl":null,"url":null,"abstract":"Conventional eye-tracking methods require NIR-LEDs at the corners and edges of displays as references. However, extensive eyeball rotation results in the loss of reflections. Therefore, we propose imperceptible markers that can be dynamically displayed using liquid crystals. Using the characteristics of polarized light, the imperceptible markers are shown on a screen as references for eye-tracking. Additionally, the marker positions can be changed using the eyeball pose in the previous frame. The point-of-gaze was determined using the imperceptible markers based on model-based eye gaze estimation. The accuracy of the estimated PoG obtained using the imperceptible marker was approximately 1.69°, higher than that obtained using NIR-LEDs. Through experiments, we confirmed the feasibility and effectiveness of relocating imperceptible markers on the screen.","PeriodicalId":339393,"journal":{"name":"2022 Symposium on Eye Tracking Research and Applications","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Gaze Estimation with Imperceptible Marker Displayed Dynamically using Polarization\",\"authors\":\"Yutaro Inoue, Koki Koshikawa, K. Takemura\",\"doi\":\"10.1145/3517031.3529640\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Conventional eye-tracking methods require NIR-LEDs at the corners and edges of displays as references. However, extensive eyeball rotation results in the loss of reflections. Therefore, we propose imperceptible markers that can be dynamically displayed using liquid crystals. Using the characteristics of polarized light, the imperceptible markers are shown on a screen as references for eye-tracking. Additionally, the marker positions can be changed using the eyeball pose in the previous frame. The point-of-gaze was determined using the imperceptible markers based on model-based eye gaze estimation. The accuracy of the estimated PoG obtained using the imperceptible marker was approximately 1.69°, higher than that obtained using NIR-LEDs. Through experiments, we confirmed the feasibility and effectiveness of relocating imperceptible markers on the screen.\",\"PeriodicalId\":339393,\"journal\":{\"name\":\"2022 Symposium on Eye Tracking Research and Applications\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 Symposium on Eye Tracking Research and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/3517031.3529640\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 Symposium on Eye Tracking Research and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3517031.3529640","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

传统的眼球追踪方法需要在显示器的角落和边缘放置nir - led作为参考。然而,眼球的大范围旋转会导致反射的损失。因此,我们提出了可以使用液晶动态显示的不易察觉的标记。利用偏振光的特性,将难以察觉的标记显示在屏幕上,作为眼球追踪的参考。此外,可以使用前一帧中的眼球姿势来改变标记位置。使用基于模型的人眼注视估计的不可察觉标记来确定注视点。使用不可见标记获得的PoG估计精度约为1.69°,高于使用NIR-LEDs获得的精度。通过实验,我们证实了移动屏幕上难以察觉的标记的可行性和有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Gaze Estimation with Imperceptible Marker Displayed Dynamically using Polarization
Conventional eye-tracking methods require NIR-LEDs at the corners and edges of displays as references. However, extensive eyeball rotation results in the loss of reflections. Therefore, we propose imperceptible markers that can be dynamically displayed using liquid crystals. Using the characteristics of polarized light, the imperceptible markers are shown on a screen as references for eye-tracking. Additionally, the marker positions can be changed using the eyeball pose in the previous frame. The point-of-gaze was determined using the imperceptible markers based on model-based eye gaze estimation. The accuracy of the estimated PoG obtained using the imperceptible marker was approximately 1.69°, higher than that obtained using NIR-LEDs. Through experiments, we confirmed the feasibility and effectiveness of relocating imperceptible markers on the screen.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信