多层建筑太阳能水泵的设计、实施及成本分析

Mohammad Rejwan Uddin, Mohammad Rabiul Hossen, K. M. Salim
{"title":"多层建筑太阳能水泵的设计、实施及成本分析","authors":"Mohammad Rejwan Uddin, Mohammad Rabiul Hossen, K. M. Salim","doi":"10.1109/ICGET.2015.7315110","DOIUrl":null,"url":null,"abstract":"Electric motors are used to pump water in multistoried building. Total power consumed by those motors is huge in urban area. By implementing a renewable energy source to run those motors can save energy from national grid. The purpose of this paper is to provide information about planning and installation of solar powered water pumping systems by using Thin Film PV (Photo Voltaic) Module. 20 panels of 95 Watt are mounted by using movable concrete pillar for flexibility. A 3D design was created by using SketchUp 3D to bring perfection in mounting solar panels. A three phase inverter is used to operate with higher output voltage of Thin Film PV Module. To avoid starting torque and maintenance cost, a three phase 2 HP AC water pump is used for pumping water. A four storied building is considered to lift water from reserve tank on ground. The system has been tested successfully in delivering 500 liter water in 17 minutes to the over head reserve tank at broad sunlight. Total cost for installing this project is also analyzed in this paper.","PeriodicalId":404901,"journal":{"name":"2015 3rd International Conference on Green Energy and Technology (ICGET)","volume":"20 5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Design, implementation and cost analysis of a solar powered water pump for multistoried building\",\"authors\":\"Mohammad Rejwan Uddin, Mohammad Rabiul Hossen, K. M. Salim\",\"doi\":\"10.1109/ICGET.2015.7315110\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electric motors are used to pump water in multistoried building. Total power consumed by those motors is huge in urban area. By implementing a renewable energy source to run those motors can save energy from national grid. The purpose of this paper is to provide information about planning and installation of solar powered water pumping systems by using Thin Film PV (Photo Voltaic) Module. 20 panels of 95 Watt are mounted by using movable concrete pillar for flexibility. A 3D design was created by using SketchUp 3D to bring perfection in mounting solar panels. A three phase inverter is used to operate with higher output voltage of Thin Film PV Module. To avoid starting torque and maintenance cost, a three phase 2 HP AC water pump is used for pumping water. A four storied building is considered to lift water from reserve tank on ground. The system has been tested successfully in delivering 500 liter water in 17 minutes to the over head reserve tank at broad sunlight. Total cost for installing this project is also analyzed in this paper.\",\"PeriodicalId\":404901,\"journal\":{\"name\":\"2015 3rd International Conference on Green Energy and Technology (ICGET)\",\"volume\":\"20 5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 3rd International Conference on Green Energy and Technology (ICGET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICGET.2015.7315110\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 3rd International Conference on Green Energy and Technology (ICGET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICGET.2015.7315110","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

在多层建筑中,电动机用于抽水。在城市地区,这些电机消耗的总功率是巨大的。通过采用可再生能源来运行这些电机,可以节省国家电网的能源。本文的目的是提供关于利用薄膜PV(光伏)模块规划和安装太阳能水泵系统的信息。20块95瓦的面板采用可移动的混凝土支柱安装,以提高灵活性。使用SketchUp 3D创建了一个3D设计,以完美地安装太阳能电池板。采用三相逆变器使薄膜光伏组件的输出电压更高。为避免启动扭矩和维护成本,水泵采用三相2hp交流水泵。一个四层楼的建筑被认为是从地面上的蓄水池中抽水。该系统已经在17分钟内成功地在阳光下将500升水输送到头顶的储水箱中。本文还对该工程的安装总成本进行了分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design, implementation and cost analysis of a solar powered water pump for multistoried building
Electric motors are used to pump water in multistoried building. Total power consumed by those motors is huge in urban area. By implementing a renewable energy source to run those motors can save energy from national grid. The purpose of this paper is to provide information about planning and installation of solar powered water pumping systems by using Thin Film PV (Photo Voltaic) Module. 20 panels of 95 Watt are mounted by using movable concrete pillar for flexibility. A 3D design was created by using SketchUp 3D to bring perfection in mounting solar panels. A three phase inverter is used to operate with higher output voltage of Thin Film PV Module. To avoid starting torque and maintenance cost, a three phase 2 HP AC water pump is used for pumping water. A four storied building is considered to lift water from reserve tank on ground. The system has been tested successfully in delivering 500 liter water in 17 minutes to the over head reserve tank at broad sunlight. Total cost for installing this project is also analyzed in this paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信