免疫荧光法测定ca19 -9和ca125。

M Plebani, D Faggian, M Masiero, A Giacomini, A Burlina
{"title":"免疫荧光法测定ca19 -9和ca125。","authors":"M Plebani,&nbsp;D Faggian,&nbsp;M Masiero,&nbsp;A Giacomini,&nbsp;A Burlina","doi":"10.1515/cclm.1990.28.12.919","DOIUrl":null,"url":null,"abstract":"<p><p>We evaluated a new immunoluminometric technique (ILMA) for the measurement of the cancer antigens, CA 19-9 and CA 125 in serum. A satisfactory reproducibility was found, coefficients of variation ranging from 4.2 to 7.3% in within-run and between-run assays. The linearity of tests was maintained over a wide concentration range. Mean analytical recovery was 94% for CA 19-9 and 98% for CA 125. A significant agreement between results obtained by immunoradiometric assays and evaluated methods was found both for CA 125 (ILMA = 0.917 IRMA + 1.048; r = 0.966; n = 98) and CA 19-9 (ILMA = 1.156 IRMA + 0.996; r = 0.995; n = 100).</p>","PeriodicalId":15649,"journal":{"name":"Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie","volume":"28 12","pages":"919-21"},"PeriodicalIF":0.0000,"publicationDate":"1990-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1515/cclm.1990.28.12.919","citationCount":"5","resultStr":"{\"title\":\"CA 19-9 and CA 125 determination by immunoluminometric assay.\",\"authors\":\"M Plebani,&nbsp;D Faggian,&nbsp;M Masiero,&nbsp;A Giacomini,&nbsp;A Burlina\",\"doi\":\"10.1515/cclm.1990.28.12.919\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We evaluated a new immunoluminometric technique (ILMA) for the measurement of the cancer antigens, CA 19-9 and CA 125 in serum. A satisfactory reproducibility was found, coefficients of variation ranging from 4.2 to 7.3% in within-run and between-run assays. The linearity of tests was maintained over a wide concentration range. Mean analytical recovery was 94% for CA 19-9 and 98% for CA 125. A significant agreement between results obtained by immunoradiometric assays and evaluated methods was found both for CA 125 (ILMA = 0.917 IRMA + 1.048; r = 0.966; n = 98) and CA 19-9 (ILMA = 1.156 IRMA + 0.996; r = 0.995; n = 100).</p>\",\"PeriodicalId\":15649,\"journal\":{\"name\":\"Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie\",\"volume\":\"28 12\",\"pages\":\"919-21\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1515/cclm.1990.28.12.919\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/cclm.1990.28.12.919\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/cclm.1990.28.12.919","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

我们评估了一种新的免疫荧光技术(ILMA)用于检测血清中癌症抗原CA 19-9和CA 125。重复性良好,运行内和运行间的变异系数为4.2 ~ 7.3%。在较宽的浓度范围内,试验保持线性。ca19 -9的平均分析回收率为94%,ca125为98%。免疫放射测定结果与评估方法之间的显著一致性发现CA 125 (ILMA = 0.917 IRMA + 1.048;R = 0.966;n = 98)和CA 19-9 (ILMA = 1.156 IRMA + 0.996;R = 0.995;N = 100)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
CA 19-9 and CA 125 determination by immunoluminometric assay.

We evaluated a new immunoluminometric technique (ILMA) for the measurement of the cancer antigens, CA 19-9 and CA 125 in serum. A satisfactory reproducibility was found, coefficients of variation ranging from 4.2 to 7.3% in within-run and between-run assays. The linearity of tests was maintained over a wide concentration range. Mean analytical recovery was 94% for CA 19-9 and 98% for CA 125. A significant agreement between results obtained by immunoradiometric assays and evaluated methods was found both for CA 125 (ILMA = 0.917 IRMA + 1.048; r = 0.966; n = 98) and CA 19-9 (ILMA = 1.156 IRMA + 0.996; r = 0.995; n = 100).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信