{"title":"场退化交联聚乙烯电缆的极化和去极化电流分析","authors":"S. Sulaiman, A. M. Ariffin, T. M. Kuan, M. Osman, N. H. Nik Ali, H. Illias","doi":"10.1109/ICPADM49635.2021.9493953","DOIUrl":null,"url":null,"abstract":"Gradual deterioration in polymeric cable insulation system, whether due to continuous applications of high voltages or ageing mechanisms, may lead to eventual cable failure and subsequent electricity disruption. This has led to the growth in need for power utility companies to explore methods to closely monitor and assess the health of cable insulation, through condition-based monitoring (CBM) exercises. Polarization and depolarization current (PDC) analysis is a non-destructive insulation monitoring method that has been widely applied to assess the health of insulation for high voltage equipment especially power transformers. This study proposes to expand on the recent interest in PDC’s assessment of cross-linked polyethylene (XLPE) cable insulation degradation. It attempts to investigate the PDC behaviour by performing experimental and simulation studies on in-service field degraded XLPE cables. Comparisons between PDC measurements and simulations for 39 field cables saw matching patterns in terms of categorization by conductivity values. Based on works done by established researchers, a five level PDC based CBM categorization for cable maintenance was proposed, ranging from healthy to moderately degraded to severely degraded cable insulation conditions. Comparison between the proposed and existing PDC based CBM table of a power utility company saw a 76.92% match, suggesting that the technique can be used to ascertain cable insulation degradation.","PeriodicalId":191189,"journal":{"name":"2021 IEEE International Conference on the Properties and Applications of Dielectric Materials (ICPADM)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Polarization and Depolarization Current Analysis for Field Degraded Cross Linked Polyethylene Cables\",\"authors\":\"S. Sulaiman, A. M. Ariffin, T. M. Kuan, M. Osman, N. H. Nik Ali, H. Illias\",\"doi\":\"10.1109/ICPADM49635.2021.9493953\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Gradual deterioration in polymeric cable insulation system, whether due to continuous applications of high voltages or ageing mechanisms, may lead to eventual cable failure and subsequent electricity disruption. This has led to the growth in need for power utility companies to explore methods to closely monitor and assess the health of cable insulation, through condition-based monitoring (CBM) exercises. Polarization and depolarization current (PDC) analysis is a non-destructive insulation monitoring method that has been widely applied to assess the health of insulation for high voltage equipment especially power transformers. This study proposes to expand on the recent interest in PDC’s assessment of cross-linked polyethylene (XLPE) cable insulation degradation. It attempts to investigate the PDC behaviour by performing experimental and simulation studies on in-service field degraded XLPE cables. Comparisons between PDC measurements and simulations for 39 field cables saw matching patterns in terms of categorization by conductivity values. Based on works done by established researchers, a five level PDC based CBM categorization for cable maintenance was proposed, ranging from healthy to moderately degraded to severely degraded cable insulation conditions. Comparison between the proposed and existing PDC based CBM table of a power utility company saw a 76.92% match, suggesting that the technique can be used to ascertain cable insulation degradation.\",\"PeriodicalId\":191189,\"journal\":{\"name\":\"2021 IEEE International Conference on the Properties and Applications of Dielectric Materials (ICPADM)\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE International Conference on the Properties and Applications of Dielectric Materials (ICPADM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPADM49635.2021.9493953\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE International Conference on the Properties and Applications of Dielectric Materials (ICPADM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPADM49635.2021.9493953","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

聚合物电缆绝缘系统的逐渐恶化,无论是由于持续的高压应用还是老化机制,都可能导致最终的电缆故障和随后的电力中断。这导致电力公司越来越需要探索通过状态监测(CBM)活动密切监测和评估电缆绝缘状况的方法。极化去极化电流(PDC)分析是一种非破坏性的绝缘监测方法,已广泛应用于高压设备特别是电力变压器的绝缘健康评估。本研究提出了扩展PDC对交联聚乙烯(XLPE)电缆绝缘退化评估的最新兴趣。它试图通过对现场使用的退化XLPE电缆进行实验和模拟研究来研究PDC的行为。将39条现场电缆的PDC测量值与模拟结果进行比较,发现了电导率值分类方面的匹配模式。根据已有研究人员的工作,提出了基于PDC的电缆维护CBM的5级分类,从健康、中等退化到严重退化的电缆绝缘状况。将该方法与某电力公司现有的基于PDC的CBM表进行对比,拟合度为76.92%,表明该方法可用于确定电缆绝缘劣化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Polarization and Depolarization Current Analysis for Field Degraded Cross Linked Polyethylene Cables
Gradual deterioration in polymeric cable insulation system, whether due to continuous applications of high voltages or ageing mechanisms, may lead to eventual cable failure and subsequent electricity disruption. This has led to the growth in need for power utility companies to explore methods to closely monitor and assess the health of cable insulation, through condition-based monitoring (CBM) exercises. Polarization and depolarization current (PDC) analysis is a non-destructive insulation monitoring method that has been widely applied to assess the health of insulation for high voltage equipment especially power transformers. This study proposes to expand on the recent interest in PDC’s assessment of cross-linked polyethylene (XLPE) cable insulation degradation. It attempts to investigate the PDC behaviour by performing experimental and simulation studies on in-service field degraded XLPE cables. Comparisons between PDC measurements and simulations for 39 field cables saw matching patterns in terms of categorization by conductivity values. Based on works done by established researchers, a five level PDC based CBM categorization for cable maintenance was proposed, ranging from healthy to moderately degraded to severely degraded cable insulation conditions. Comparison between the proposed and existing PDC based CBM table of a power utility company saw a 76.92% match, suggesting that the technique can be used to ascertain cable insulation degradation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信